Instructions / Assembly
Table Of Contents
9
6
Top track
fastener locations
Assembly and Installation Instructions
for Smooth-Pro
™
F-4500 Fiberglass Folding Wall System (JII-90076)
FASTEN PRODUCT (SIZE AND SPACING)
Embedment must be a minimum of 1 1/4" into the
structural framing. Fastener (anchor) heads must be ush.
1. Fasten the head jamb
through the pre-drilled
hole locations using the
provided installation
fasteners. NOTE: A shim
is required at each
fastening location to
prevent frame deection.
Pre-drilled
hole
Sealant
Shim
Sill
Interior
Exterior
Sill Pan
Rough
Opening
Sealant
Fasteners through the sill will breach the sill pan
ashing. Following the sealant application steps
outlined below is imperative.
• Apply sealant to the threads of the fasteners. Apply additional
sealant into and around the pre-drilled hole.
• Seat the fastener until the head is ush with the frame.
• Apply sealant to the fastener head, ensuring the head is sealed to
the frame.
2. Apply sealant and fasten the
sill through each pre-drilled
hole location (located beneath
the rubber sill track seal).
15"
15"
3. Unlock and open the slabs to gain access to the pre-drilled fastener
locations behind the side jamb weatherstrip.
4. Fasten the side jamb at the
pre-drilled locations.
NOTE: DO NOT pinch or
rip the weatherstrip on the
side jambs.