Instructions / Assembly

2
Installation Instructions
for Pre-Hung Exterior Entry Doors (JII106)
INSPECT ROUGH OPENING (R.O.)
The use of a sill pan and other barriers will decrease
the rough opening height clearance. Adjust the
opening dimensions accordingly.
Rough Opening Requirements
Verify the width and height of the rough opening is 1/2" larger than
the patio door width and height.
Verify the rough opening
Verify Square, Level and Plumb
is square. The (A) and (B)
measurements should be the
same. Suggested deviation
from square is no more
A
than1/4".
Verify the rough opening is
C
E
level and plumb (C, D and E).
Suggested deviation is no more
D
than 1/4".
B
The rough opening sill should
not be crowned or sagged
(D), but rather level or sloped
(positive slope) to the exterior.
The exterior face of the rough opening should be in a single plane (E)
with less than 1/8" twist from corner to corner.
Minimum double studs (king and jack/trimmer) should be used to
support the header at all rough openings.
For Retrot Installations
Verify the rough opening framing is structurally sound. Contact your local
waste management entities for proper disposal or recycling of products
being removed.
This installation guide only addresses masonry/block wall, sheathed
wall, open-stud construction and exterior foam insulation. For
exterior foam insulation construction, please reference the latest
version of FMA/AAMA/WDMA 500 for additional install and
framing details. If installing into an opening other than what is
identied, consult a building professional.
Masonry/Block Wall Construction
This installation assumes
that a framework of
studs (often called a
buck) has already been
properly fastened in a
weatherproof manner to
the concrete/masonry wall.
Buck
The patio door will be
mounted into the buck in a
weatherproof manner.
Fully Sheathed Wall Construction
Sheathing is applied to the
exterior of the wall framing.
The patio door will be
mounted ush against the
sheathing or building wrap
in a weatherproof manner.
Flashing
Sheathing
Sill area
Building
Wrap
Open-Stud Construction
Sheathing is absent
and building wrap is
applied atop of the wall
framing. The patio door
will be mounted into
the rough opening in a
Open Stud
weatherproof manner.
Flashing
Sill area
Building
Wrap
4