Tech Sheet

FOR SERVICE TECHNICIAN’S USE ONLY
22
Test Name Description Steps
TEST #6
RTD Left Oven
Temperature
Sensor
To check: RTD function is good.
Example:
F6E3
1. Unplug range or disconnect power.
2. Remove door and toe panel to access main control.
3. Verify that ALL connectors are inserted all the way into the main control.
4. Check connector J3 on the left control REB board. Make sure it is plugged in and fully seated.
If it is not, make the proper connection and go to step 8.
5. Disconnect the J3 connector and measure indicated temperature sensor resistance value of
the RTD from J3-1 and J3-2 from the harness side. The resistance values should read: Oven
Sensor(s) - Between 931 and 2869 Ω (approximately 1080 Ω at room temperature).
If the temperature sensor does meet the requirements, go to step 8.
6. Remove back panels and ensure the indicated temperature sensor is plugged in properly and
fully inserted. See “Component Locations” section.
If it is not, plug it into the connector and go to step 8.
7. Disconnect the RTD from the main harness and measure resistance from RTD connector. The
resistance values should read: Oven Sensor(s) - Between 931 and 2869 Ω (approximately 1080Ω
at room temperature).
If it’s out of range, the oven sensor is improperly functioning, and needs to be replaced.
8. Reassemble all parts and panels. Plug in range or reconnect power.
9. Wait 3 minutes before checking if there is an error.
If there is an error, go to service mode to check if the error code is F6E3 (Left Oven Over
Temperature Limit).
1
J3
Strobe
Door Switch
Left Temp Sensor
Pressure switch