Tech Sheet

FOR SERVICE TECHNICIAN’S USE ONLY
28
Test Name Description Steps
TEST #10
(Continued)
10. If the cooling fan is on but the error is still occurring, reassemble all parts and panels. Plug in
range or reconnect power and enter diagnostic mode to check if it is the same cooling fan error
code F8E1 (low speed error) or F8E2 (high speed error). If there are no cooling fan errors (F8E0 or
F8E2), go to step 11.
11. Go to the service diagnostics manual test mode to turn on the low speed cooling fan. Visually
check and if fan is on, go to step 14.
12. If the cooling fan is not on, unplug range or disconnect power. Connect a voltmeter between
P6-4 and J5-2, plug in range or reconnect power and measure AC voltage.
If 120 VAC is not present, unplug range or disconnect power and replace the REB control.
13. If 120 VAC is present, unplug range or disconnect power. Connect voltmeter between the black
wire and white wire on the cooling fan. Plug in range or reconnect power and measure AC
voltage.
If 120 VAC is present, but the fan is not on, cooling fan is improperly functioning. Unplug range or
disconnect power.
14. After replacing components, run step 7 again to ensure the issue has been xed.
15. Reassemble all parts and panels. Plug in range or reconnect power.