Installation guide

NATURAL GAS TO PROPANE GAS (LP) CONVERSION INSTRUCTIONS
TO CONVERT APPLIANCE FOR USE WITH PROPANE GAS
Propane conversion is to be performed by a JENN-AIR
AUTHORIZED SERVICE CONTRACTOR (or other
qualified agency) in accordance wfth the manufacturer's
instructions and all codes and requirements of the
authority having jurisdiction. Failure to follow
instructions could resu t in senous injury or property
damage. The qualified agency performingthis work
assumes responsibility for this conversion.
Natural gas supply line must have a natural gas service
regulator. Inlet pressure to this appliance should be
reduced to a maximum of 14 inches water column (0.5
pounds per square inch (P.S.I.) liquified petroleum
(L.P.)/propane gas supply line must have a LP. gas
pressure regulator. Inlet pressure to this appliance
should be reduced to a maximum of 14 inches water
column [0.5 P.S.I.). Inlet pressures in excess of 0.5
P.S.I. can damage the appliance pressure regulator
and other gas components in this appliance and can
result in a gas leak.
I WA..,.G
ELECTRICAL POWER AND GAS MUST BE
TURNED OFF PRIOR TO CONVERSION. 1
Manifold - Propane Gas pressure required - 10" Water
Column.
Incoming Propane Gas pressure required to regulator-
11" - 14" Water Column.
Propane Gas conversion Orifice Hoods are supplied with
these models.
PROPANE CONVERSION
INCHES
BURNER BTU/hr DIAMETER COLOR
Left Rear (LR) 8,000 .033 Zinc
Left Front (LF) 8,000 .033 Zinc
Right Rear (RR) 8,500 .035 Green
Right Front (RF) 8,500 .035 Green
-14-