Dimension Guide

JENN-AIR
®
DETAILED PLANNING DIMENSIONSJENN-AIR
®
DETAILED PLANNING DIMENSIONS
2 of 3
8560CdZw815
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air
®
appliances are appropriately UL, CUL or CSA approved.
D* G
E
A
B
B
I
K
J
H
C
e
F
Side
Cabinet
H
D*
G
I**
K
J**
E
C
e
BB
H
F
H
Side
Cabinet
A
D*
G
I**
K
J**
E
C
e
BB
H
F
H
Side
Cabinet
A
MODEL # JEC4430B
in cm
A
Width of combustible area above
cooking surface (min.)
30 76.2
B
Width from cooktop to fixed wall or
other combustible material (min.)
1 2.5
C
Width to outer edge of outlet (max.) 9 23.0
D*
Height to bottom of uncovered wood or
metal cabinet above cooking surface (min.)
30
76.2
E
Height to bottom of uncovered wood or
metal cabinet (min.)
18 45.7
F
Height to top edge of outlet (min.) 7 17.8
G
Depth of upper cabinet 13
33.0
H
Depth from cutout to wall (min.) 1 2.5
I
Width of cutout (recommended) 29
1
2 74.9
J
Depth of cutout (recommended) 20
1
2 52.0
K
Depth from cutout to front of countertop 2
5
8 6.7
e
Recommended electrical access location
* Dimension can be reduced by 6" (15.2 cm) when bottom of wood or metal
cabinet is covered by not less than
1
4" (0.6 cm) flame retardant millboard
covered with not less than No. 28 MSG sheet metal, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
If installing a hood or microwave hood combination above the cooktop,
follow the hood or microwave hood combination instructions for
dimensional clearances above the cooking surface.
OPENING/CLEARANCE DIMENSIONS
FRONT VIEW
TOP VIEWSIDE VIEW
30" ELECTRIC RADIANT COOKTOP WITH ELECTRONIC TOUCH CONTROL
JEC4430BS – 31" x 5
5
16" x 22
3
16"
JEC4430BB – 30
7
8" x 5
5
16" x 21
11
16"
ELECTRICAL REQUIREMENTS
A 3-wire or 4-wire, single phase, 120/240 volt, 60 Hz., AC only electrical
supply is required on a separate, 40-amp circuit fused on both sides of
the line. 48" (121.9 cm) of
1
2" (1.3 cm) I.D. flexible cable is provided.
LOCATION REQUIREMENTS
To ensure cooktop base clearance, cabinet side walls need to be wider
than the cutout.
If cabinet has a drawer, allow a 5
1
2" (14.0 cm) minimum clearance
between countertop and top of drawer.
COOKTOP OVER SINGLE WALL OVEN INSTALLATION
REQUIREMENTS
For approved model number combinations, refer to the under counter
label on the bottom of the cooktop burner box.
• To install a cooktop over a single wall oven, refer to page 3.