Installation guide

Step 6: Place 9.2k burner choke(s) into right rear and
left front orifice holder with chamfer facing down. (See
figure 10).
BURNE R CAP
SCREWS
9.2 kROK[--__ BURNER BASE
Step 7" Place 15k burner choke into center orifice
holder. (See figure 11).
Step 8: Replace burner base, caps, and grates.
Tighten screws (do not cross thread) to 25-30 in Ibs.
Step 9: Save the orifices removed from the appliance
for future use.
BURNER CAP
SCREWS
BURNER BASE
CONVERSION OF APPLIANCE PRESSURE
REGULATOR
CONVERTEB_
cAP I
NDPIN..
NAT I J'_
p./ !
LP
APPLYDOWNWARD
FINGERPRESSURE
ATDISCEDGESTO
REPLACEPININCAP
APPLYSIDEWARD
..,., RNGERPRESBtlRE
TOREMOVEPIN
FROMOAP
NAT I IL-P
FIGURE12
C. LOW FLAME ADJUSTMENT (See figure 13)
This appliance is shipped from the factory with low and
high flame settings adjusted for use with natural gas.
To set for use with LP proceed as follows:
1. Remove control knob from valve stem.
.CAUTIpN_: NEVER USE A METAL BLADE TO
PRY KNOB OFFI IF KNOB CANNOT BE EASILY
REMOVED, TUCK THE FOLDS OF A CLOTH
DISHTOWEL UNDERTHE KNOB AND PULL THE
TOWEL UPWARD WITH STEADY; EVEN PRES_
SURE.
2. Carefully remove rubber grommet.
3. Locate the valve adjustment screw. See figure 13.
4. Insert a slender, thin-blade screwdriver into knob
hole and engage blade with slot in adjusting screw.
5. Turn the adjusting screw clockwise until tight (5-7
in-lbs max.). Do not over tighten.
6. Replace rubber grommet and control knob.
7. Repeat for remaining burners.
VIEW THROUGH KNOB HOLE
ORIFICE $PUD_ RIFICE HOLDER
FIGURE11
B. INVERT CAP IN APPLIANCE PRESSURE
REGULATOR (See figure 12)
With the appliance installed, the appliance regulator
should be located as shown in figure 3 or 4.
SCREW
KNOB
(KNOB REMOVED)
ART#O215-187-O
FIGURE 13