Installation guide
ConversionTo LP Gas
This applianceis shippedfrom the factory equipped for use
with Natural Gas. To convert it from Natural Gas for use with
LP Gas, perform steps 1 through 4.
1. Remove natural gas orifice hoods. Install color coded
orifice hoods supplied, located in a pack attached to the
outer plenum area of this appliance. (See illustration "E"
below, and LP Gas Conversion Instructions on page 6).
2. Invert cap in convertible appliance pressure regulator (if
so equipped) located at entrance to gas manifold.
3. Adjust air shutterson individual burners for proper flame
appearance.
4. Adjust low flame setting at each burner by turning
adjustment screw in center of valve stem.
To make these conversion adjustments follow the
instructions and illustrations ("A" through "E" on
pages 3 - 4).
iApply a non-corrosive leak detection fluid to alljoints and
fittings in the gas connection between the supply fine
shut-off valve and the range. Include gas fittings and
joints in the range if connections were disturbed during
installation. Check for leaks! Bubbles appearing around
fittings and connections will indicate a leak. If a leak
appears, turn off supply hnegas shut-off valve and retest
for leaks. Never test for gas leaks with an open flame.
This applianceis shippedfrom the factorywith orifice hoods
ddlledfor usewithNatural Gas. Toconvertfrom Natural Gas
toLP, applya 1/2"open-endwrenchtohexsectionoforifice
hood.TURN COUNTERCLOCKWISE TO REMOVE. Save
the Natural Gas orifice hoods just removed from this
appliance for future use. Instatl color coded odfice hoods
supplied. (See LP Gas Conversion Instructions above and
page 6). TURN CLOCKWISE TO INSTALL. Hold dimension
specifiedin Illustration"E".
I_OPEN END
WRENCH
TURN
CLOCKWISE
TO TIGHTEN
TURN
COUNTERCLOCKWISE
TO REMOVE ORIFICE HOOD
iLLUSTRATION "E"
ControlSettings
The size and type ofcookwara and the amountand type of
food being cooked wi(Iinfluence the settingneeded forbest
cookingresults. The setting indicated should serve as a
guide whileyou become familiar with your cooktop.
Use the HI flame setting to
quickly bring foods to a boil or
to begin a cooking operation.
Then reduce to a lower
setting to continue cooking.
Never leave food unattended
over a HI flame setting.
Mad setting is used to
continue a cooking opera-
tion. Food will not cook any
faster when a HI flame
setting is used than that is
needed to maintain a gentle
boil. Remember, water boils
at the same temperature
whether boiling gently or
vigorous},/.
Use Lo setting to keep food
at serving temperatures
withoutfurther cooking. You
may find that some cooking
may take place if the
cookware is covered.
|
I
Minimum Spacing Requirement
Convertible Gas Cooktops
For installing a Double Bay Downdraft
Cooktop in combination with another
Downdraft Cooktop, the minimum spacing
between adjacent units must be provided, as
shown, for satisfactoryperformance.
DOUBLE BAY
DOUBLE BAY