Installation guide

TO CONVERTAPPLIANCEFORUSE WITH PROPANEGAS
Natural Gas To Propane Gas (LP) ConversionInstructions
...,, .
__ Authorized Service Contractor(or
otherqualifiedagency) in accordancewith the
_man_s:!nstructlons anda, codesand
='_uL_'n_, ,of _the , authority having
u_o_ Failure to follow instructions could
.,_ult_ serious "injury or property damage. The
_ualif!_ agency performing this work assumes
responsibility for this conversion.
r
Models - JGD8130 & JGD8345 Series
Manifold - Propane Gas pressure required - 10" W.C.
Incoming Propane Gas pressure required to appliance
pressureregulator- 11" - 12" W,C.
Propane Gas conversionorifice hoods are suppliedwith
these models•
Propane Gas input specified - JGD8130/JGD8345 -
33,000 BTUthr / 51,000 BTU/hr.
F.LECTmCAL e, S.UST
TURNEDOFF PRIOR.TOC0¢__:' r_,
®
TIE DOWN
BOLT ON
EACH END
GREASE
CONTAINER
REGULATOR
BLOWERCANBE
SWIVELED90°
JGD8345(Shown)
INCHES
BURNER BTU/hr ORIFICE DIAMETER COLOR
Left Rear (LR) 7,500 #66 .0330 Zinc
Left Front (LF) 7,500 #66 .0330 Zinc
Right Rear (RR) 9,000 #63 .0310 Blue
Right Front (RF) 9,000 #63 .0370 Blue
Center Rear (CR) 9,000 #63 .0370 Blue
Center Front (CF) 9,000 #63 .0370 Blue