Installation guide

Gas Supply
Installationof thisrange must conformwith localcodes or,in the
absenceof localcodes,with the NationalFuelGasCode,ANSIZ223.t-
latestedition.InCanadathe rangemustbe installedin accordance
withthe currentCGAStandardCAN/CGA-Bt49- InstallationCodesfor
GasBurningAppliancesand Equipmentand/orlocalcodes.
In TheCommonwealthOfMassachusetts
Thisproduct must be installedbya licensedplumberorgasfitter when
installedwithinthe Commonwealthof Massachusetts,A "T" handle
type manual gas valve must be installed in the gas supply line to this
appliance.A flexible gas connector,when used,must not exceeda
length of three (3)feet / 36 inches.
Gas leaks may occurin your system and result in a dangerous
situation. Gasleaks may not be detected by smell alone,Gas
suppliers recommend you purchaseand install an ULapproved
gas detector. Install and use in accordance with manufacturer,s
instructions.
A QUALIFIED SERVICEMAN OR GAS APPLIANCE INSTALLER
MUST MAKE THE GASSUPPLYCONNECTION,Leak testing of the
appliance shall be conducted by the installer according to the
instructions given in Step 7,
Applya non-corrosive leak detection fluid to all joints and fittings in
the gas connectionbetween the supply line shut-off valve and the
range. Includegas fittings and joints in the range if connections were
disturbed during installation. Checkfor leaks! Bubblesappearing
aroundfittings and connectionswill indicate a leak. If a leak appears,
turn off supply line gasshut-off valve,tighten connections,turn onthe
supply line gasshut off valve,and retest for leaks.
CAUTION:NEVERCHECK FORLEAKSWITH A FLAME.WHEN
LEAKCHECKIS COMPLETE,WIPE OFF ALL RESIDUE,
NATURALGASSUPPLYLINEMUSTHAVEA NATURALGASSERVICE
REGULATOR.INLETPRESSURETOTHISAPPLIANCESHOULDBE
REDUCEDTOA MAXIMUMOF14INCHESWATERCOLUMN(0.5 POUNDS
PERSQUAREINCH(RS.I.)LIQUEFIEDPETROLEUM(L.P.)/PROPANEGAS
SUPPLYLINEMUSTHAVEA L.R GASPRESSUREREGULATOR.INLET
PRESSURETOTHISAPPLIANCESHOULDBEREDUCEDTOA MAXIMUM
OF14INCHESWATERCOLUMN(0.5 P.S.I.).INLETPRESSURESIN
EXCESSOF0.5 RS.I.CANDAMAGETHEAPPLIANCEPRESSURE
REGULATORANDOTHERGASCOMPONENTSINTHISAPPLIANCEAND
CANRESULTINA GASLEAK.
Gassupply pressurefor testingregulatormustbe at least1" water
columnpressureabovemanifoldpressureshownonserialplate.
Check Pressure of House Piping System
1.The appliance and its individualshutoff valvemust be
disconnectedfrom the gassupply pipingsystem duringany
pressuretestingofthatsystem at test pressuresinexcessof
1/2 Ibs./sq.in. (3.5 kPa)(13,8 in. water column).
2.The appliance mustbe isolatedfrom the gassupply piping
system by closingitsindividualmanualshutoff valveduringany
pressuretestingofthe gassupply pipingsystem at test
pressuresequal to or lessthan 1/2 Ibs,/sq.in. (3.5 kPa)
(13.8 in.water column).
A GASSHUT-OFFVALVESHOULDBEPUTINANACCESSIBLELOCATION
INTHESUPPLYLINEAHEADOFTHERANGE,FORTURNINGONAND
TURNINGOFFGASSUPPLY.CONNECTORNUTSMUSTNOTBE
CONNECTEDDIRECTLYTOPIPETHREADS.THECONNECTORSMUSTBE
INSTALLEDWITHADAPTORSPROVIDEDWITHTHECONNECTOR.
Thehouse piping and/or range connector used to connect the range to
the main gas supply must be clean, free of metal shavings, rust, dirt
and liquids (oil or water). Dirt,etc. in the supply lines can work its way
into the range manifold and in turn cause failure of the gasvalves or
controls and clog burners and/or pilot orifices.
NOTE:It isrecommendedtousea newCSAcertified 1/2" flexible connectornolonger than36" (91.4 cm) with a minimumBTU/HRrating of
60,000 be used.Rigidpipe may alsobe used.
I i[llf l ill ;t LvAiliVl;L*I i =11;!,'t ;tviililijc
Follow these procedures to remove appliance for servicing:
1. Slide rangeforward todisengagerange from the anti-tipbracket,
2. Shut off gassupply toappliance.
3. Disconnectelectrical supply to appliance,if equipped.
4. Disconnectgassupply tubingto appliance.
5. Reverseprocedureto reinstall, If gaslinehasbeendisconnected, THE APPLIANCE.
checkfor gas leaksafter reconnection.
6.Topreventrange from accidentally tipping,rangemustbe secured tothe floor by sliding rearlevelingleg intothe anti-tip bracket,
NOTE:A qualified servicer should disconnect and reconnect the gas supply. Theservicer MUSTfollow installation instructions provided with the gas
appliance connector and the warning label attached to the connector.
:!II/.'Iii 11lvi / [Ill]
Whenyour range requires service or replacement parts,contact your dealer or authorized service agency.Please give the complete model and serial
number of the range which is located on front frame behindstorage drawer.
J Your not be equippedwith some of the features referred to in this manual.
range may
|