15. Plug in oven or reconnect power.
16. Verify operation is normal. Enter the Diagnostics menu, select “Error
Diagnostics,” and clear thehistory.
FAILURE ERROR LIKELY FAILURE CONDITION
F2
Keypad
E0 Keypad disconnected
E1 Stuck/Shorted keypad
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven(power off, wait 10
seconds, and power on).
PROCEDURE: Before proceeding, verify the error codeby entering the
Diagnostics mode and selecting “Error Diagnostics.”
1. Unplug oven or disconnect power.
2. Check that connectors J4, J5, J6, and J7 are rmly connected. If they are
not, go to Step 3. If they are, go to Step 6.
3. Reconnect any loose connectors.
4. Reassemble all parts and panels before operating.
5. Plug in oven or reconnect power. If the failure is gone, go to Step 9. If the
failure is still present, unplug oven or disconnect power.
6. Replace the Control Panel Assembly.
7. Reassemble all parts and panels before operating.
8. Follow the on-screen prompts to select the model number.
9. Verify operation is normal. Enter the Diagnostics menu, select “Error
Diagnostics,” and clear the history. If the Control Panel Assembly was
replaced, there is no need to clear the error history.
HMI Right
J7J5
J15
User Interface
J4J6
HMI Left
1 2 3 4
Control Panel Assembly
RD
BK
Speaker
J8