Component Testing Chart - Oven
To properly check for voltage, complete the following steps:
1. Unplug oven or disconnect power.
2. Connect voltage measurement equipment tocheckpoints.
3. Plug in oven or reconnect power and conrmvoltagereading.
4. Unplug oven or disconnect power.
Component Serviceable Side Check Points Copernicus Results-Resistance Results-Voltage
Lights Front P7-1 to L1 (J8-1) 0-40 Ω 120 V
Latch Switch Front P3-7 to P3-5 Open circuit
Door Switch Front P3-6 to P3-5 Closed circuit with oven door closed
Latch Motor Front P5-1 to N (J8-2) 500-3000 Ω 120 V motor running
Oven Temperature Sensor Front P3-1 to P3-2 1075 Ω at 68°F (20°C) DLB
Meat Probe Side P3-3 to P3-4 9876-10075 Ω
Blower Motor - HighSpeed Rear P5-5 to N (P7-1) 15-23 Ω 120 V motor running
Blower Motor - LowSpeed Rear P5-4 to N (J8-2) 15-23 Ω 120 V motor running
Thermal Limiter Rear PX3-1 to L2 (Main line) Closed circuit 0 V closed, N/A open
Convection Fan* Rear P5-3 to N (J8-2) 16-20 Ω 120 V motor running
Convection Element* Front PX1-3 to PX3-2 16.63-18.38 Ω
240 V Convection cycle
operating
Bake Element Rear PX1-1 to PX3-2 19.0-21.6 Ω
240 V Bake cycle
operating
Broil Element Front PX4-2 to PX3-2 13.5-14.92 Ω 240 V Broil cycle operating