Tech Sheet
FOR SERVICE TECHNICIAN’S USE ONLY
6
General Procedure: System Information
NOTE: This procedure is to view the following system information:
System Information Display
Model # Model Information
Serial # Product Serial Number
UI Serial # User Interface Serial Number
Oven ACU Serial # Appliance Control UnitSerialNumber
UI Version User Interface Software Version
HMI Central SW HMI Central Board SoftwareVersion
HMI Left SW HMI Left Keyboard SoftwareVersion
HMI Left EE HMI Left Keyboard EEPROMVersion
HMI Right SW HMI Right Keyboard SoftwareVersion
HMI Right EE HMI Right Keyboard EEPROMVersion
Kernel Version HMI Central Board SoftwareVersion
Touch Calibration Version LCD/TP FPC Tail SoftwareVersion
Database Version HMI Central Board DatabaseStructure
Audio Version HMI Central Board SoftwareVersion
Oven ACU SW
Oven Appliance Control UnitSoftware
Version
MWO ACU SW
Microwave Oven Appliance Control
Unit Software Version
Diagnostics Entries
Number of times Diagnostics menu has
been entered.
1. Plug in oven or connect power.
2. Enter Diagnostics mode.
3. Touch or scroll to “System Information” in the Diagnostics menu, and
then touch “OK.”
4. Touch or scroll through the System Information menu to view the desired
status.
NOTE: Touching “Back” will return the display to the main Diagnostics
menu.
General Procedure: Model Selection
NOTE: When a new User Interface (UI) is installed, you will beprompted to
select a new model number upon power-up. To change the model number on
an existing UI,follow the steps below.
1. Plug in oven or connect power.
2. Enter Diagnostics mode.
3. Touch or scroll to “System Information” in theDiagnostics menu, and
then touch “OK.”
4. Touch or scroll to “Model Number,” and then touch“OK.”
5. Touch or scroll to the correct model number inthelist, and then touch
“Select.”