Installation Instructions

7
Electrical Requirements - Canada Only
Be sure that the electrical connection and wire size are adequate
and in conformance with the CSA Standard C22.1, Canadian
Electrical Code, Part 1 - latest edition, and all local codes and
ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
Check with a qualified electrical installer if you are not sure
the range is properly grounded.
*The NEC calculated load is less than the total connected load
listed on the model/serial/rating plate.
When a 4-wire, single phase 250 volt, 60 Hz., AC only
electrical supply is available, a 40-amp minimum circuit
protection is required on 30" (76.2 cm) ranges, fused on both
sides of the line.
A time-delay fuse or circuit breaker is recommended.
This range is equipped with a UL or CSA International
Certified Power Cord intended to be plugged into a standard
14-50R wall receptacle. Be sure the wall receptacle is within
reach of range’s final location.
Do not use an extension cord.
The wiring diagram is located on the back of the range or in a
clear plastic bag.
Range Rating* Specified Rating of Power
Supply Cord Kit and
Circuit Protection
120/240 Volts 120/208 Volts Amps Temp Rating
8.8 - 16.5 kW
16.6 - 22.5 kW
7.8 - 12.5 kW
12.6 - 18.5 kW
40 or 50
50
194°F (90°C)
194°F (90°C)