SITE PREP
MULTIPLE COLUMN REFRIGERATION
1. CHECK THE FURNITURE
Measure to make sure all opening dimensions are correct.
Side panel construction: 3/4" (1.9 cm) thick plywood.
IMPORTANT: Cannot be constructed of pressed fiber material such
as MDF.
Soffit height: 84" (213.4 cm).
The bottom panel must consist of 3⁄4" plywood.
The offset between the bottom edge of the soffit cabinet’s bottom
rail and the 3⁄4" bottom plywood must not exceed 1⁄8".
The 3⁄4" plywood bottom panel must extend laterally to directly
contact the left and right side panels and be securely fastened along
its depth.
A single water supply line may be split 2 or 3 ways to service all
columns.
2. CHECK THE INSTALLATION SITE
Away from ovens, radiators or other heat sources.
Temperature will not fall below 55° F (13° C).
Floor supports more than 600 lbs. (272 kg)
plus door panel and contents weight.
Floor level with the room.
Furniture face plumb.
WARNING
Explosion Hazard
Keep flammable materials and vapors, such
as gasoline, away from refrigerator.
Failure to do so can result in death,
explosion, or fire.
WARNING
Tip Over Hazard
Refrigerator is top heavy and tips easily when
not completely installed.
Keep doors taped closed until refrigerator is
completely installed.
Use two or more people to move and install
refrigerator.
Follow installation instructions.
Failure to do so can result in death or serious
injury.
Soffit cabinet
Soffit cabinet
bottom rail
Soffit cabinet base panel extends
to side panels (both sides)
Max. offset 1/8"
3/4"
84"