Parts Supplied
Check that all parts are included.
Anti-tip bracket kit
NOTE: Anti-tip bracket must be securely mounted to
suboor. Thickness of ooring may require longer screws
toanchor bracket to suboor. Longer screws are available
from your local hardware store. See the “Install Anti-Tip
Bracket” section.
Burner grates
Burner caps
Griddle drip tray (on griddle models)
Additional Parts Supplied on Steam-Assist Models (on some
models)
Model W10049700 water lter kit
1/4" (6.4 mm) to 1/4" (6.4 mm) water supply union
Parts Needed
All models must be installed with a backguard if installing
at zero clearance to a combustible back wall surface such
as drywall. See “Cabinet Dimensions” in the “Location
Requirements” section for installation requirements.
Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See the “Electrical Requirements”
and “Gas Supply Requirements” sections.
It is recommended that all electrical connections be made by
alicensed, qualied electrical installer.
Additional Parts Needed on Steam-Assist Models (on some
models)
Tubing staples/retainers
1/4" (6.4 mm) O.D. exible codes-approved water supply
tubing (to make water connection)
Water connection device (to connect 1/4" (6.4 mm) O.D.
tubing to water source). Check local codes for type of
connection required.
High Altitude Conversion
To convert the range for elevations above 6,560 ft (2000 m),
order a High Altitude Conversion Kit.
Part Number W11238043: High altitude kit
NOTE: Both propane and natural gas conversions are included
in the high altitude kit.
To order, see the “Assistance or Service” section of the Use
andCare Guide.
Water Filtration System Location
Requirements
(on some models)
For best results, do not install the water ltration system outside
or in extreme hot or cold temperatures. Temperature of water
supply to the water ltration system must be between 40°F (4°C)
and 100°F (38°C). Do not install on hot water supply line.
Locate the water ltration system near the cold water supply
pipe under the kitchen sink to lter cold water.
Make sure that the water lter assembly is installed in the upright
position.
It will be necessary to drill a 1/2" (1.3 cm) minimum diameter
hole in the upper-right or left rear corner of the side wall of the
cabinet under the sink to route the water supply tubing through
to the range.
Depending on your installation conguration, more routing holes
may be required.
Coil enough exible codes-approved water supply tubing behind
the range to allow for the connection to the range to be made
behind the range prior to setting the range in place.
Typical Installation Configuration
NOTE: For unique installations, contact a licensed plumber.
In Massachusetts, a licensed plumber is required and the
Commonwealth of Massachusetts Plumbing Code 248-CMR will
be adhered to.
Water Supply Requirements
A cold water supply with water pressure between 30 and 120 psi
(207 and 827 kPa) is required to operate the steam feature. In
Massachusetts, plumbing code 248 CMR 3.00 and 10.00 must
be followed, and a licensed plumber will be used. If you have
questions about your water pressure, call a licensed, qualied
plumber.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out of
a reverse osmosis system going to the water inlet valve of the
range needs to be between 30 and 120 psi (207 and 827 kPa).
If a reverse osmosis water ltration system is connected to your
cold water supply, the water pressure to the reverse osmosis
system needs to be a minimum of 40 psi (276 kPa).
If the water pressure to the reverse osmosis system is less than
40 psi (276 kPa):
Check to see whether the sediment lter in the reverse
osmosis system is blocked. Replace the lter, if necessary.
Allow the storage tank on the reverse osmosis system to rell
after heavy usage.
If you have questions about your water pressure, call a licensed,
qualied plumber.
A
B
A. Anti-tip bracket
B. #8-18 x 1" (2.5 cm) Phillips head screws (4)
Cold water
supply
Hot
Cold
Filter
assembly
location