7
48" (121.9 cm) models
NOTE: When installed in a 24" (61.0 cm) base cabinet with 25"
(63.5 cm) countertop; front of oven door protrudes 1
7
/
8
" (4.8 cm)
beyond 24" (61.0 cm) base cabinet.
Cabinet Requirements
Cabinet opening dimensions shown are for 25" (64.0 cm)
countertop depth, 24" (61.0 cm) base cabinet depth, and
36"(91.4 cm) countertop height. Dimensions must be met
inorder to ensure a ush t to back wall.
IMPORTANT: If installing a range hood or microwave hood
combination above the cooking surface, follow the range hood
or microwave hood combination installation instructions for
dimensional clearances above the cooking surface.
** Minimum Clearances
30" (76.2 cm) models: 42" (106.7 cm) minimum clearance
between the top of the cooking platform and the bottom of a
combustible surface
36" (91.4 cm) models: 58" (147.3 cm) minimum clearance
between the top of the cooking platform and the bottom of a
combustible surface
48" (121.9 cm) models: 58" (147.3 cm) minimum clearance
between the top of the cooking platform and the bottom of a
combustible surface
*** If the surface of the back wall is constructed of a combustible
material and a backguard is not installed, a 6" (15.2 cm)
minimum clearance is required for all models.
C
D
B
A
A. 27
1
⁄
8
" (68.9 cm) depth with control panel (See NOTE.)
B. 35
3
⁄
4
" (90.8 cm) range height when sitting on the wheels
C. 48" (121.9 cm) width
D. Model/serial/rating plate location/SAID label
(located on front side panel)
M
K
N
G
I
F
D
E
B
C
**
A
H
I
L
J
Electrical
installation
area*
Gas
installation
area
J
F
O***
A. 18" (45.7 cm) upper cabinet to countertop
B. 30" (76.2 cm) model: 30" (76.2 cm) min. upper cabinet width
36" (91.4 cm) model: 36" (91.4 cm) min. upper cabinet width
48" (121.9 cm) model: 48" (121.9 cm) min. upper cabinet width
C. 13" (33 cm) max. upper cabinet depth
D. For minimum clearance to top of range.**
E. 30" (76.2 cm) on 30" (76.2 cm) models
36" (91.4 cm) on 36" (91.4 cm) models
48" (121.9 cm) on 48" (121.9 cm) models
F. 12" (30.4 cm) min. clearance from both sides of range to side
wall or other combustible material
G. 15" (38.1 cm)
H. 22" (55.9 cm) on 30" (76.2 cm) models
28" (71.1 cm) on 36" (91.4 cm) models
40" (101.6 cm) on 48" (121.9 cm) models
I. 4" (10.1 cm)
J. 3" (7.6 cm)
K. 5" (12.7 cm)
L. 6" (15.2 cm) on 30" (76.2 cm) models
14" (35.5 cm) on 36" (91.4 cm) models
24" (61.0 cm) on 48" (121.9 cm) models
M. 10
1
/
2
" (26.7 cm)
N. 6" (15.2 cm)
O. 6" (15.2 cm)***