Smart Appliances Guide

PARTS & ASSEMBLIES
Connected Smart Appliances - Gen III
n
3-5
For Service Technician Use Only
Reference power line
BLACK
WIRE
(CT-)
WHITE
WIRE
(CT+)
Current Transformer (CT)
Real power is measured using current transformer(s).
n The current transformers act like an amp probe that
measure current usage so that actual power can be
calculated.
n Appliances using L2 have two current transformers,
CT1 and CT2 (L1 and L2 respecvely).
n Current Transformers are integrated into the appliance
wiring harness on all models.
The output of the Current Transformer(s) is connected to the
Power Management Board at connector J4, pins 1 & 2 (CT1)
and if L2 exists, pins 3 & 4 (CT2).
Typical Current Transformer assembly shown in gure 5.
Figure 5 - Current Transformer
Figure 6 - Current Transformer Schematic
Black face
of current
transformer
towards power
source
Direction of
primary current flow
BLACK
WIRE
(CT-)
WHITE
WIRE
(CT+)
2500T