Smart Appliances Guide

SMART DRYER
Connected Smart Appliances - Gen III
n
6-5
Smart Dryer Component Tests
Smart Dryer Component Tests
Perform the following test procedure to verify soware
for the WiFi and Power Management boards. If any of the
components do not generate a soware revision number,
check all connecons to and from the components. If
connecons test good, replace the aected component.
ACTIVATING SERVICE DIAGNOSTIC MODE
1. Be sure the dryer is in standby mode (plugged in with all
indicators o).
2. Select any three (3) buons (except POWER) and follow
the steps below, using the same buons (remember the
buons and the order that the buons were pressed):
Within 8 seconds,
Press and Release the 1st selected buon,
Press and Release the 2nd selected buon,
Press and Release the 3rd selected buon;
Repeat this 3 buon sequence 2 more mes.
3. If this test mode has been entered successfully, all
indicators on the console will be illuminated for 5 seconds
with “888” showing in the three-digit display and a tone
will sound. If there are no saved fault codes, all indicators
on the console will momentarily turn o, and then only
the seven segment display will come back on and display
888.
NOTE: The Service Diagnosc mode will me out aer
10 minutes of user inacvity, or shut down if AC power is
removed from the dryer.
EXITING SERVICE DIAGNOSTIC MODE
Use either of the two methods below to exit diagnosc mode.
Press and hold the 1st buon used to acvate the
Service Diagnosc mode for 5 seconds.
Press the POWER buon once or twice, depending on
diagnosc procedure.
SOFTWARE VERSION DISPLAY
NOTE: The Soware Version Display mode will me out aer
10 minutes of user inacvity and return to standby mode.
Entry Procedure
To enter Soware Version Display, press and hold the 2nd
buon used to acvate the Service Diagnosc mode for 5
seconds. Upon entry, the display will automacally cycle
through the following informaon:
UI soware revision code (U: major revision number, U:
minor revision number, U: test revision number)
UI cycle GEE revision code (y: major revision number, y:
minor revision number, y: test revision number)
UI HW GEE revision code (H: major revision number, H:
minor revision number, H: test revision number)
UI touch control soware revision code (t: major
revision number, t: minor revision number, t: test
revision number)
UI touch parameters revision code (o: major revision
number, o: minor revision number, o: test revision
number)
UI audio soware revision code (A: major revision
number, A: minor revision number, A: test revision
number)
ACU soware revision code (C: major revision number,
C: minor revision number, C: test revision number)
ACU GEE revision code (h: major revision number, h:
minor revision number, h: test revision number)
WI-FI soware le revision code (n: major revision
number, n: minor revision number, n: test revision
number)
ACU cycle designer revision code (d: major revision
number, d: minor revision number, d: test revision
number)
Power Measurement Module (PMM) soware le
revision code (p: major revision number, p: minor
revision number, p: test revision number)
Exit Procedure
Pressing the POWER buon will exit Soware Version Display
and return dryer to standby mode.