Smart Appliances Guide

8-4
n
Connected Smart Appliances - Gen III
SMART REFRIGERATOR
Smart Refrigerator Component Tests
Press and hold the Recommended buon. While holding the Recommended buon, press and hold the Drawer
buon simultaneously and hold both buons for 5 seconds. (Figure 6)
No countdown will display. When Service Mode is accessed, a chime will play.
NOTE: Recommended indicator will not light up in the main screen and may be dicult to locate.
Service mode
requirement
Buon on Main UI
Enter Service Key
Combinaon
“—” and “—” temperature
buons pressed for
3 seconds
Enter Key for Navigaon “Icemaker2” buon
Increment Key for
Navigaon
” Up buon
Decrement Key for
Navigaon
“ V ” Down buon
Back Key for Navigaon “Fast Cool” buon
Use arrow keys to move between service test modes. Enter
test mode by selecng Icemaker2 buon.
Once in the Diagnoscs mode push and hold the Up arrow
to advance to the rst Wi-Fi Service Test.
Service Test - 106 Wi-Fi Link Connection Self Test
While the test is in progress, the display will show: “00” –
Link Tesn Progress.
Following the compleon of the Link Test, the display will
transion to the following code designaon: “01” – Not
able to link with AP or WISE.
“02” – Not able to link with WISE. “03” – Connected to AP
and WISE.
Service Test - 108 WI-FI Antenna 1 Signal Strength
Display the measured value as a percentage of possible
range. The possible range to the technician is 0% to 100%.
Service Test - 109 WI-FI Antenna 2 Signal Strength
Display the measured value as a percentage of possible
range. The possible range to the technician is 0% to 100%.
House LED
House symbol becomes an
amber color only
if the user has “opt-in” or set
up the Energy
Service Test - 110 Display Current Smart Grid Mode
Display “0” for Smart Grid Mode not acve, “1” for delay
ice making Smart Grid Mode acve, “2” for delay ice
making and cooling Smart Grid Mode acve.
Service Test - 111 Smart Grid Mode 1 Counter
Displays the number of mes the unit has entered Smart
Grid Mode
1. Allowable range is from 0 to 999 instances.
Service Test - 112 Smart Grid Mode 2 Counter
Displays the number of mes the unit has entered Smart
Grid Mode
2. Allowable range is from 0 to 999 instances.
To Exit Service Diagnoscs Mode:
Set to 0, you will exit the test mode.
If in a service test mode, back out using Fast Cool buon.
Next press and hold the Recommend buon. While
holding the Recommended buon press, and hold the
Drawer buon, hold both buons for 5 seconds.
Figure 6