Smart Appliances Guide
8-4
n
Connected Smart Appliances - Gen III
SMART REFRIGERATOR
Smart Refrigerator Component Tests
• Press and hold the Recommended buon. While holding the Recommended buon, press and hold the Drawer
buon simultaneously and hold both buons for 5 seconds. (Figure 6)
• No countdown will display. When Service Mode is accessed, a chime will play.
• NOTE: Recommended indicator will not light up in the main screen and may be dicult to locate.
Service mode
requirement
Buon on Main UI
Enter Service Key
Combinaon
“—” and “—” temperature
buons pressed for
3 seconds
Enter Key for Navigaon “Icemaker2” buon
Increment Key for
Navigaon
“ ” Up buon
Decrement Key for
Navigaon
“ V ” Down buon
Back Key for Navigaon “Fast Cool” buon
Use arrow keys to move between service test modes. Enter
test mode by selecng Icemaker2 buon.
Once in the Diagnoscs mode push and hold the Up arrow
to advance to the rst Wi-Fi Service Test.
Service Test - 106 Wi-Fi Link Connection Self Test
• While the test is in progress, the display will show: “00” –
Link Tesn Progress.
• Following the compleon of the Link Test, the display will
transion to the following code designaon: “01” – Not
able to link with AP or WISE.
• “02” – Not able to link with WISE. “03” – Connected to AP
and WISE.
Service Test - 108 WI-FI Antenna 1 Signal Strength
• Display the measured value as a percentage of possible
range. The possible range to the technician is 0% to 100%.
Service Test - 109 WI-FI Antenna 2 Signal Strength
• Display the measured value as a percentage of possible
range. The possible range to the technician is 0% to 100%.
House LED
House symbol becomes an
amber color only
if the user has “opt-in” or set
up the Energy
Service Test - 110 Display Current Smart Grid Mode
• Display “0” for Smart Grid Mode not acve, “1” for delay
ice making Smart Grid Mode acve, “2” for delay ice
making and cooling Smart Grid Mode acve.
Service Test - 111 Smart Grid Mode 1 Counter
• Displays the number of mes the unit has entered Smart
Grid Mode
1. Allowable range is from 0 to 999 instances.
Service Test - 112 Smart Grid Mode 2 Counter
• Displays the number of mes the unit has entered Smart
Grid Mode
2. Allowable range is from 0 to 999 instances.
To Exit Service Diagnoscs Mode:
• Set to 0, you will exit the test mode.
• If in a service test mode, back out using Fast Cool buon.
Next press and hold the Recommend buon. While
holding the Recommended buon press, and hold the
Drawer buon, hold both buons for 5 seconds.
Figure 6