ELECTRICAL REQUIREMENTS
120 V, 60 Hz, AC-only, 15 A or 20 A fused electrical supply. Copper
wire only. A time delay fuse or circuit breaker and separate circuit
is recommended.
WATER SUPPLY REQUIREMENTS
120°F (49°C) hot water supply with water pressure between
20 psi and 120 psi (138 kPa and 862 kPa) is required. If you have
questions about your water pressure, call a licensed, qualified
plumber.
DRAIN REQUIREMENTS
Connect drain hose to waste tee or disposer inlet above drain
trap. Maximum recommended length of drain hose is 12 ft (3.7
m) that meets all current AHAM/ IAPMO test standards and is
resistant to heat and detergent.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING