Dimension Guide

JENN-AIR® DETAILED PLANNING DIMENSIONS
4 of 4
8989dZw117
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide
before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air
®
appliances are appropriately UL, CUL or CSA approved.
DOWNDRAFT COOKTOP DUCTING ARRANGEMENTS
The diagrams below show typical duct arrangements for downdraft cooktops. JX3™ downdraft cooktops
also offer a duct-free installation option. For more details, refer to page 3.
DUCTING CONFIGURATIONS
CALCULATING MAXIMUM DUCTING LENGTH
Maximum ducting length is 60' (18.3 m).
Each 90° elbow equals 5' (1.5 m) duct.
Use no more than three 90° elbows.
Flexible metal vent is not recommended.
• Do not install two elbows together.
NOTES:
For ducting runs up to 30' (9.1 m), install cooktop as shipped.
For ducting runs of 31' (9.4 m) to 60' (15.2 cm), remove the restricter
ring on the blower inlet housing.
For altitudes above 4500' (1272.0 m), reduce recommended vent run
by 20% for best performance.
DUCTING REQUIREMENTS
COOKTOP DUCT LENGTH DUCT SIZE
Gas
10' (3.0 m) or less*
5" (12.7 cm)
diameter*
Between 10' (3.0 m)
and 60' (18.3 m)
6" (15.2 cm)
diameter
3
1
4" x 10"
(8.3 cm x 25.4 cm)
Electric
10' (3.0 m) or less**
5" (12.7 cm)
diameter**
Between 10' (3.0 m)
and 60' (18.3 m)
6" (15.2 cm)
diameter
3
1
4" x 10"
(8.3 cm x 25.4 cm)
*Gas cooktops must use 5" (12.7 cm) diameter for runs of 10' (3.0 m) or less.
** May be used to vent straight out the back of the cooktop and directly through
the wall.
Roof jack
Transition elbow
3
1
4" x 10"
(8.3 cm x 25.4 cm) duct –
54' (16.5 m) max.
3
1
4" x 10"
t
Transition elbow
6" (15.2 cm) diameter duct –
51
1
2' (15.7 m) max.
6" (15.2 cm)
diameter wall cap
5" (12.7 cm ) to 6" (15.2 cm)
diameter transition
6" (15.2 cm)
diameter elbow
REAR DUCTING THROUGH WALL TO OUTSIDE
REAR DUCTING IN WALL TO ROOF
THROUGH FLOOR BETWEEN JOISTS TO OUTSIDE
SIDE DUCTING IN TOE KICK TO OUTSIDE