Dimension Guide

JENN-AIR® DETAILED PLANNING DIMENSIONS
2 of 4
8989dZw117
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide
before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air
®
appliances are appropriately UL, CUL or CSA approved.
30" JX3 ELECTRIC RADIANT DOWNDRAFT COOKTOP
JED3430G – 30
7
8" x 17
29
32" x 23"
OPENING/CLEARANCE DIMENSIONS
MODEL # JED3430G
in cm
A
Width of combustible area above
cooking surface (min.)
30 76.2
B
Width from cooktop to fixed wall
or other combustible material (min.)
2
1
2 6.4
C
Width to center of vent opening option (min.)
8
11
32 21.2
D
Width to outer edge of outlet (min.)
10 25.4
E*
Height to bottom of uncovered wood or
metal cabinet above cooking surface (min.)
30 76.2
F
Height to bottom of uncovered wood
or metal cabinet (min.)
18 45.7
G
Height to center of vent opening option
13
13
16 35.1
H
Height to top edge of outlet (min.)
12 30.5
I**
Depth to center of vent opening option 16
17
64 41.3
J
Depth of upper cabinet (recommended)
13 33.0
K
Depth from cutout to wall (min.)
1
1
2 3.8
L
Width of cutout
28
7
8 73.3
M
Depth of cutout
21
1
8 53.7
N
Depth from cutout to front of countertop (min.)
2 5.1
e
Recommended electrical access location
v
Recommended venting location –
see page 3-4 for ducting information
* Dimension can be reduced by 6" (15.2 cm) when bottom of wood or metal cabinet
is covered by not less than
1
4" (0.6 cm) flame retardant millboard covered with not
less than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm)
aluminum or 0.020" (0.5 mm) copper.
** Based on installation in a 24" (61.0 cm) deep by 34
1
2" (87.6 cm) high base
cabinet with a 1
1
2" (3.8 cm) thick counter top.
ELECTRICAL REQUIREMENTS
220 volt, 60 Hz, AC only, 40-amp fused, electrical circuit is required. A dedicated
circuit is recommended.
VENTING REQUIREMENTS
This cooktop must be exhausted outdoors unless using the duct-free filter kit
(JDA7000WX). Refer to kit instructions for further information.
LOCATION REQUIREMENTS
To ensure cooktop base clearance, cabinet side walls need to be wider than the cutout.
A minimum clearance of 6" (15.2 cm) is recommended between the side of the
cooktop and side wall for maximum ventilation performance.
A minimum clearance of 2" (5.1 cm) is recommended between the blower motor
and cabinet for proper cooling. A 6" (15.2 cm) clearance is recommended for
servicing access.
• An under counter built-in oven cannot be installed under this cooktop.
Side
Cabinet
E*
J
L
N
M
F
D
e
A
B
B
K
v
C
I**
K
H
v
G
C
Side
Cabinet
E*
J
L
N
M
F
D
e
A
B
B
K
v
C
I**
K
H
v
G
C
Side
Cabinet
E*
J
L
N
M
F
D
e
A
B
B
K
v
C
I**
K
H
v
G
C
FRONT VIEW
SIDE VIEW TOP VIEW – CUTOUT