Installation Guide

15
Floor Venting
1. Determine where within the template area that the vent
will exit. Mark the vent hole for the type of venting you are
using.
IMPORTANT: Check for obstructions (plumbing, electrical,
etc.) before marking the vent hole location.
2. Draw and cut the vent hole in the oor.
3. Install the blower outlet adapter to the blower vent using
three 8-18 x 3/8" (9.5 mm) screws. Seal the connection with
aluminum foil tape.
4. Remove three felt pads from the gasket strip.
5. Remove the paper backing from the felt pads and apply
the bottom of a blower motor tabs.
NOTE: Felt pads reduce motor noise and aid in mounting
to uneven oors.
6. Position the blower motor in the cabinet opening so that
the blower exhaust venting aligns with the vent hole cut
in Step 2.
IMPORTANT: Make sure the blower motor is positioned
within the area as shown on the template.
7. Connect the house vent system to the blower outlet adapter
using a vent clamp; then wrap connection with aluminum
tape.
8. Drill three 1/8" (3 mm) pilot holes using the blower motor
tabs as guides.
9. Remove the template.
10. Mount the blower motor to the oor with three #10 x 1"
(2.54 cm) screws provided.
Top View
11. Go to the “Make Gas Connection” section.