Owner's Manual
Table Of Contents
- RANGE SAFETY
- Range Safety
- RANGE MAINTENANCE AND CARE
- Clean Cycle
- General Cleaning
- INSTALLATION INSTRUCTIONS
- REQUIREMENTS
- Tools and Parts
- Location Requirements
- Venting Requirements
- Electrical Requirements - U.S.A. Only
- Electrical Requirements - Canada Only
- INSTALLATION
- Unpack Range
- Install Anti-Tip Bracket
- Position the Blower Location Template
- Install the Downdraft System
- Adjust Leveling Legs
- Level Range
- Electrical Connection - U.S.A. Only
- Install Blower
- Verify Anti-Tip Bracket Is Installed and Engaged
- Remove/Replace Drawer (on some models)
- Oven Door
- Complete Installation
- Moving the Range
- SECURITE DE LA CUISINIERE
- Sécurité de la cuisinière
- ENTRETIEN ET REPARATION DE LA CUISINIERE
- Programme de nettoyage
- Nettoyage général
- INSTRUCTIONS D'INSTALLATION
- SPECIFICATIONS
- Outils et pièces
- Exigences d’emplacement
- Exigences concernant l’évacuation
- Spécifications électriques – É.-U. seulement
- Spécifications électriques – Canada seulement
- INSTALLATION
- Déballage de la cuisinière
- Installation de la bride antibasculement
- Positionnement du gabarit indiquant l’emplacement du ventilateur
- Installation du circuit d’évacuation par le bas
- Réglage des pieds de nivellement
- Réglage de l’aplomb de la cuisinière
- Raccordement électrique – É.-U. seulement
- Installation du ventilateur
- Vérifier que la bride antibasculement est bien installée et engagée
- Enlever/replacer le tiroir (sur certains modèles)
- Porte du four
- Achever l’installation
- Déplacement de la cuisinière
10
Calculating Vent System Length
IMPORTANT: This range is rated at 60 ft (18.3 m) of 6" (15.2 cm)
or 30 ft (9.15 m) of 5" (12.7 cm) straight duct. To calculate the
length of the system you need, add the equivalent feet (meters)
for each vent piece used in the system.
Vent Piece 5" (12.7 cm) or 6"
(15.2 cm) Round
Straight round
45° elbow 2.5 ft
(0.8 m)
90° elbow 5.0 ft
(1.5 m)
6" (15.2 cm) wall
cap
0.0 ft
(0.0 m)
3
1
/
4
" x 10" (8.3 cm x
25.4 cm) to 6"
(15.2 cm) transition
4.5 ft
(1.4 m)
6" (15.2 cm) to 3
1
/
4
"
x 10" (8.3 cm x
25.4 cm) transition
1 ft
(0.3 m)
3
1
/
4
" x 10" (8.3 cm x
25.4 cm) to 6"
(15.2 cm) 90°
elbow transition
5.0 ft
(1.5 m)
6" (15.2 cm) to 3
1
/
4
"
x 10" (8.3 cm x
25.4 cm) 90° elbow
transition
5.0 ft
(1.5 m)
Vent Piece 5" (12.7 cm) or 6"
(15.2 cm) Round
3
1
/
4
" x 10" (8.3 cm x
25.4 cm) 90° elbow
5.0 ft
(1.5 m)
3
1
/
4
" x 10" (8.3 cm x
25.4 cm) flat elbow
12.0 ft
(3.7 m)
3
1
/
4
" x 10" (8.3 cm x
25.4 cm) wall cap
0.0 ft
(0.0 m)
Straight 3
1
/
4
" x 10"
(8.3 cm x 25.4 cm)
5" (12.7 cm)
thermal break
Part Number
708786A
6" (15.2 cm)
thermal break
Part Number
715557A
2.0 ft
(0.6 m)
Example 6" (15.2 cm) vent system
Venting Between Floor Joists
Maximum length = 60 ft (18.3 m)
1- 90° elbow = 5 ft (1.5 m)
8 ft (2.4 m) straight = 8 ft (2.4 m)
1 - wall cap = 0 ft (0 m)
System length = 13 ft (3.9 m)
NOTE: For external venting, a flexible vent is not recommended.
Flexible vents create back pressure and air turbulence that greatly
reduce performance.
Wall cap
6 ft (1.8 m)
90° elbow
2 ft
(0.6 m)