Installation Instructions

12
Install Anti-Tip Bracket
1. Determine which mounting method to use: oor or wall.
If you have a stone or masonry oor, you can use the
wallmounting method.
2. Determine and mark centerline of the cutout space. The
mounting bracket must be installed on the left side of the
cutout. Position mounting bracket in cutout as shown in the
following illustration.
Measurement B:
30” (76.2 cm) ranges: 13” (33.0 cm)
36” (91.4 cm) ranges: 16” (40.6 cm)
48” (121.9 cm) ranges: 22” (55.9 cm)
Measurement C:
Optional distance from back wall. If back wall is constructed
of a combustible material and a backguard is not installed, a
6” (15.2 cm) minimum clearance is required for all models.
Install anti-tip bracket accordingly.
3. Drill two 1/8” (3.0 mm) holes that correspond to the bracket
holes of the determined mounting method. See the following
illustrations.
Floor Mounting
Wall Mounting
4. Using a Phillips screwdriver, mount anti-tip bracket
tothewall or oor with the two #12 x 1
5
8
” (4.1 cm)
screwsprovided.
Depending on the thickness of your ooring, longer screws
may be necessary to anchor the bracket to the suboor.
Longer screws are available from your local hardware store.
5. Move range close enough to opening to allow for electrical
connections to be made. Remove shipping base, cardboard,
or hardboard from under range.
6. Continue installing your range using the following
installationinstructions.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
A
C
B
A. Centerline
B. Centerline of cutout to outside
edge of anti-tip bracket
C. Back wall to back of range
B
A
A. #12 x 1
5
8
" (4.1 cm) screws
B. Anti-tip bracket
B
A
A. #12 x 1
5
8
" (4.1 cm) screws
B. Anti-tip bracket