Flush Kit Installation Guide

3
Parts Supplied
Deector bracket
Plastic spacers - (4) single ovens, (6) double ovens
#8-18 x 1/4" (6.3 mm) screws - (2) for 27" (68.6 cm) models;
(4) for 30" (76.2 cm) models
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
NOTE: Refer to the following “Location Requirements” and the
“Location Requirements” section of the Installation Instructions
provided with your built-in oven.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance with oven.
Recessed installation area must provide complete enclosure
around the recessed portion of the oven.
Oven support surface must be solid, level, and ush with
bottom of the cabinet cutout.
Floor must be able to support a single oven weight of
180 lbs (82 kg).
Floor must be able to support a double oven weight of
357 lbs (162 kg)
IMPORTANT: To avoid damage to your cabinets, check with
your builder or cabinet supplier to make sure that the materials
used will not discolor, delaminate, or sustain other damage. This
oven has been designed in accordance with the requirements
of UL and CSA International and complies with the maximum
allowable wood cabinet temperatures of 194°F (90°C).
Deflector Bracket Dimensions
Cabinet Dimensions - Single Ovens, Flush
Installations
A 25" (63.5 cm) minimum cutout depth is required.
These dimensions will result in a 1⁄4" (6.3 mm) reveal on the top,
a 1⁄4" (6.3 mm) reveal on the sides, and a 1⁄8" (3.1 mm) reveal on
the bottom of the wall oven.
The front face of the cleats and platform will be visible and
should be treated as a nished surface.
Single Ovens Installed in Cabinet - Flush Installation
*Cleats and spacers must be recessed 1
3
/
8
" (3.5 cm) from the
front of the cabinet.
A
27" (68.6 cm) Models
A. 26
15
16
" (68.4 cm) overall width
30" (76.2 cm) Models
A. 29
15
16
" (76.0 cm) overall width
27" (68.6 cm) Models
A. 3/4" (19 mm) top cleat*
B. 27
1
/
4
" (69.2 cm) minimum width
of flush inset cutout
C. 25
7
/
8
" (65.7 cm) minimum width
of opening
D. 30
7
/
16
" (77.3 cm) minimum
height of flush inset cutout
E. 29
11
/
16
" (75.4 cm) recommended
cutout height
F. 11/16" (1.7 cm) side cleat*
G. 1/2" x 2" (1.3 cm x 5.1 cm)
spacer the entire depth of the
cutout*
H. Recommended junction box
location
I. 4
5
/
8
" - 32" (11.7 cm- 81.3 cm)
bottom of cutout to floor
J. 25" (63.5 cm) minimum depth
of cutout
30" (76.2 cm) Models
A. 3/4" (19 mm) top cleat*
B. 30
1
/
4
" (76.8 cm) minimum width
of flush inset cutout
C. 28
7
/
8
" (73.3 cm) minimum width
of opening
D. 30
7
/
16
" (77.3 cm) minimum
height of flush inset cutout
E. 29
11
/
16
" (75.4 cm) recommended
cutout height
F. 11/16" (1.7 cm) side cleat*
G. 1/2" x 2" (1.3 cm x 5.1 cm)
spacer the entire depth of the
cutout*
H. Recommended junction box
location
I. 4
5
/
8
" - 32" (11.7 cm - 81.3 cm)
bottom of cutout to floor
J. 25" (63.5 cm) minimum depth
of cutout
A
B
C
D
E
F
F
I
H
H
J
G
G
Front View Side View
06-May-2019 13:38:41 EDT | RELEASED
In some European factories the letter "W" of the part code mentioned herein will be automatically
replaced by the number "4000" (e.g. "W12345678" becomes "400012345678")