ELECTRICAL REQUIREMENTS
115 V, 60 Hz, AC only, 15 or 20 A fused, grounded circuit is required.
A dedicated circuit is recommended. Use an outlet that cannot
be turned off by a switch. Minimum length of power cord is
84" (213.4 cm). Do not use an extension cord.
WATER PRESSURE REQUIREMENTS
A cold water supply with water pressure between 30 and
120 psi (207 and 827 kPa) is required to operate the ice maker.
Call a licensed, qualified plumber with any questions about the
water pressure.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water coming out of a reverse
osmosis system going to the water inlet valve of the refrigerator
needs to be between 30 and 120 psi (207 and 827 kPa).
If a reverse osmosis water filtration system is connected to the
cold water supply, the water pressure to the reverse osmosis
system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).
LOCATION REQUIREMENTS
Floor must be able to support refrigerator (more than 600 lb
[272 kg]), door panels and contents of the refrigerator and must
be at the same level as flooring in the room.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
WARNING
Explosion Hazard
Keep ammable materials and vapors, such as
gasoline, away from refrigerator.
Failure to do so can result in death, explosion, or re.