Dimension Guide

JENN-AIR
®
DETAILED PLANNING DIMENSIONS
3 of 3
9123AdZw817
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air
®
appliances are appropriately UL, CUL or CSA approved.
OPENING/CLEARANCE DIMENSIONS
FRONT VIEW
Floor
Wall
F
A
J
e
w
B
G
I
C
D
H
EE
K
M
O
N
P
L
BACK VIEW
15" ICE MACHINES
JUIFX15H, JUIFN15H – 14
7
8" x 33
13
16" x 24
1
64" (depth without handle)
MODEL #
JUIFX15H
JUIFN15H
in cm
A
Width (min.) 15 38.1
Width without hinge side spacer option (min.) 15 38.1
Width with hinge side spacer option (min.) *15
3
4* *40.0*
B
Width of outlet location 6 15.0
C
Outlet location – distance from side 1 2.5
D
Width of water connection location 3
1
2 8.9
E
Minimum width from hinged side of ice
machine to fixed wall – door open 90°
2 5.1
Minimum width from hinged side of ice machine
to fixed wall – door fully open 180°
13
1
4 33.7
Minimum width from hinged side of ice machine
to fixed wall – door fully open 118°
6
7
8 17.4
F
Height (min.) 34 86.4
G
Height of outlet location *15
3
4* *40.0*
H
Height of water connection location 6 15.0
I
Outlet location – distance from bottom 1 2.5
J
Depth of cabinet (min.) 3
1
2 8.9
K
Water line location – distance from side 2 5.1
L
Power supply – distance from side 13
1
4 33.7
M
Drain hose – distance from side 6
7
8 17.4
N
Power supply – distance from bottom 1
1
4 3.2
O
Drain hose – distance from bottom 2
7
8 7.3
P
Water line location – distance from bottom 14
17
32 36.9
e
Recommended electrical connection location
w
Recommended water connection location
* Install
3
4" (1.9 cm) front hinge-side spacer flush with face of adjacent cabinet
and
3
4" (1.9 cm) back hinge-side spacer 6" (15.2 cm) from back wall.
ELECTRICAL REQUIREMENTS
115 volt, 60 Hz, AC only, 15- or 20-amp fused, grounded circuit is required.
A dedicated circuit is recommended. Use an outlet that cannot be turned off
by a switch. Do not use an extension cord.
WATER PRESSURE REQUIREMENTS
A cold water supply with water pressure between 30 and 120 psi (207 and
827 kPa) is required to operate the ice maker. Call a licensed, qualified plumber with
any questions about the water pressure.
Reverse Osmosis Water Supply
IMPORTANT: The use of a reverse osmosis system with this product is not
recommended. However if you do use reverse osmosis, follow these instructions.
IMPORTANT: The pressure of the water coming out of a reverse osmosis system
going to the water inlet valve of the ice machine needs to be between 30 and 120
psi (207 and 827 kPa).
If a reverse osmosis water filtration system is connected to the cold water supply, the
water pressure to the reverse osmosis system needs to be a minimum of
40 to 60 psi (276 to 414 kPa).
Floor
Wall
F
A
J
e
w
B
G
I
C
D
H
EE
K
M
O
N
P
L
Floor
Back Wall
F
A
J
e
w
B
G
I
C
D
H
EE
K
M
O
N
P
L
SIDE VIEW