Installation Instructions

SITE PREPARATION | 9
SITE PREPARATION
SITE PREPARATION
IMPORTANT:
This ice maker has been designed for flush
install in instances where the power supply,
water supply, and drain are located in a
cabinetry.
For installation of product with utilities
behind the ice maker, flush install may not
be achieved.
Refer “Location Requirement” illustration
and table below for utility slot/hole cutout
location.
Utility Slot/Cutout Location Zone
Dimension
A 9" (22.9 cm)
B 8" (20.3 cm)
C 7" (17.8 cm)
Diameter of the hole D 2" (5 cm)
ELECTRICAL REQUIREMENTS
Electrical Requirements
Power Supply 115 V, 60Hz, AC only
Circuit Breaker 15 to 20 A, fused
Receptacle 3 prong grounding-type
Outlet Non-GFCI
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result
in death, fire, or electrical shock.
WARNING
IMPORTANT:
Use an outlet that cannot be turned off by a
switch. Do not use an extension cord.
It is recommended that this product not be
connected to a GFCI (Ground Fault Circuit
Interrupter) protected outlet, as nuisance
tripping of the power supply may occur.
The ice maker must be grounded. The
ice maker is equipped with a power
supply cord having a grounded 3 prong
plug. The cord must be plugged into a
mating, grounded, 3 prong wall receptacle,
grounded in accordance with the National
Electrical Code and local codes and
ordinances. If a mating wall receptacle is
not available, it is the personal responsibility
of the customer to have a properly
grounded 3 prong wall receptacle installed
by a qualified electrician.