Owner's Manual

ASSISTANCE | 15
ASSISTANCE
ASSISTANCE
PERFORMANCE DATA SHEET
ICE MAKER WATER FILTRATION SYSTEM
MODEL P6GEG2KL, P6KG2KL, P6WG2KL CAPACITY 2000 GALLONS 7571 LITERS
This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the
system, as specified in NSF/ANSI Standards 42.
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Inuent
Inuent Challenge
Concentration
Maximum
Efuent
Average
Efuent
Minimum %
Reduction
Average % Reduction
Chlorine Taste/Odor 50% reduction 1.9727 mg/L 2.0 mg/L ± 10% 0.71 mg/L 0.7788 mg/L 70.2 72.81
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.50 gpm (1.89 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 2000 gallons (7571 liters).
It is essential that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as advertised.
Use replacement filter P6RFWG2K, P6RFGEG2K, P6RFKG2K, Part
Number ICE2.
Style 1– When the water filter status display changes from “GOOD” to
“ORDER,” order a new filter. When the filter indicator reads “REPLACE,”
it is recommended that you replace the filter.
Style 2– Press FILTER to check the status of your water filter. If the filter
indicator light is yellow and the words “ORDER FILTER” appear on the
display screen, order a new filter. If the filter indicator light is red, it is
recommended that you replace the filter.
These contaminants are not necessarily in your water supply. While
testing was performed under standard laboratory conditions, actual
performance may vary.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Refer to the “Warranty” section for the Manufacturer’s name, address
and telephone number.
Refer to the “Warranty” section for the Manufacturer’s limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply Potable City or Well
Water Pressure 30-120 psi (207 - 827 kPa)
Water Temperature 33°-100°F (0.6° - 37.8°C)
Service Flow Rate 0.50 gpm (1.89 Lpm) @ 60 psi
System tested and certified by NSF International
against NSF/ANSI Standard 42 for the reduction
of Chlorine Taste and Odor.
®
NSF is a registered trademark of NSF International.