AIR CLEANER
The air cleaner is of the dry, replaceable type. One of the most important service requirements
for long term maintenance free operation is to replace or clean the air cleaner element regularly.
Excessive wear, high oil consumption and poor performance will
result if the air cleaner is clogged or allows contamination to enter
the compressor. Refer to maintenance instructions in Section 5 for
service instructions and intervals for cleaning or replacement of
element.
ADJUSTING REGULATOR
1. Pull regulator knob out
2. Turn knob clockwise to increase regulated pressure and counter clockwise to
decrease regulated pressure.
3. When desired pressure is shown on the regulated pressure gauge push knob in to
lock.
Never adjust the regulator down to the very bottom of adjustment
range, damage to the regulator may result
CONNECTING AND DISCONNECTING HOSES
To Connect:
1. Ensure that the regulated pressure gauge reads 0 PSI and that all system pressure is relieved.
2. Hold hose in hand at the quick coupler location.
3. Pull back collar or sleeve on female quick connect coupler located on the compressor.
4. Push male connector into female connector.
5. Release female connector.
6. Grasp hose and pull to ensure couplers are seated.
7. Adjust regulator to the desired pressure.
To Disconnect:
1. Ensure that the regulated pressure gauge reads 0 PSI and that all system pressure is relieved.
2. Hold hose in hand at quick coupler location.
3. Pull back collar or sleeve on female quick connect coupler located on the compressor.
4. Pull male connector out of female connector.
5. Release female connector.
Firmly grasp hose in hand when connecting or disconnecting to
prevent hose whip.
An improperly seated coupler can blow off the machine when
started.