Spec Sheet

29
3. Replace the safety hitch pin in the guard.
4. Check and/or replace the plug with the UL/CSA listed plug for the rated current and voltage.
Follow the cord plug manufacturers installation instructions and procedures or contact a qualifi ed
electrician.
Ensure that all connections are properly tightened. Improper connections could
result, causing damage, injury, or death of the equipment operator.
This machine must be connected in accordance with the National Electric Code
(NEC) Article 422-4 - Ed-31, Except as provided for in NEC 90-4.
This machine must be properly grounded to avoid fatal electrical shock in the event
of an electrical malfunction. A ground connector screw should be fastened into the
chassis to facilitate supplemental grounding as permitted by NEC 250-91.
Observe all local and national codes for the installation of this type of equipment.
If t here a re any quest ions or problems w ith the ele c t rical system being
use d ple a se, do not he sit ate in c a lling a local quali ed ele c t ric ia n.
NOISE CONSIDERATIONS
Consult local offi cials for information regarding acceptable noise levels in your area. Hearing
protection may be required if in close proximity to the compressor. To reduce excessive noise, use
vibration mounts or silencers, relocate the unit away from the work area or construct total enclosures
or baffl e walls.
LOCATION CONSIDERATIONS
Stationary Type Compressors
Stationary compressors are permanent type installations and typically are secured in place. There
are numerous ways to achieve this type of installation, the most common of which is bolting them to
directly to the fl oor or other part of the building. Often times, vibration isolators are used to reduce
noise and vibration and increase stability.
Portable Type Compressors
Portable Compressors are much more universal and can be used in almost any location as long as
reasonable care is taken. Please refer to the Danger, Warning and Cautions as to location limitations
and safe operation.
Compressors run out of level by over 10 degrees may be
permanently damaged.
Consult all local codes and standards for information regarding installation and location of
compressors as they may differ from one locale to another.
NOTICE