TROUBLESHOOTING
The following chart lists the malfunctions that occur most commonly when operating an
industrial air compressor. It gives the symptoms, their causes and the corresponding corrective
actions. In some cases, the operator or maintenance personnel can perform the corrective actions,
while others may require the assistance of a qualifi ed Jenny compressor technician or dealer.
This procedure has been written assuming that the unit has been installed correctly, has been
operating and functioning correctly. The voltage or pressure ratings listed within the troubleshooting
tables are ± 5% unless otherwise specifi ed. The dependent sequence of events are illustrated as they
must occur and to determine at what point in the troubleshooting to begin you must know what mode
of operation the malfunction is occurring. To accomplish this, the operator must read and understand
the theory of operation in chapter 4. Once you can observe the unit and recognize the modes as the
unit automatically switches into them, you should be very successful in determining what to do using
these procedures.
This unit contains lethal voltages, hazardous temperatures,
dangerous pressure and moving parts which may cause serious
injury to personnel. Perform troubleshooting with extreme
caution.
!
DANGER