Use and Care Manual

11
12.7 Lubrication
For long life and trouble-free operation, it is
essential that this machine be kept well
lubricated. The vise and leadscrew should be
oiled daily. Pivot joints and bearings should be
greased weekly.
Recommended lubricants
Grease fittings
Texaco Starplex 2 or equivalent
Vice and Leadscrew
Regal R & O 68
12.8 Air Prep Unit
The Air Prep Unit regulates the air pressure
supplied to the saw. It is located in the cabinet
stand and is accessible through the access door
located below and to the left of the control panel.
Referring to Figures 14 and 15, it consists of a
pressure regulator, pressure gauge, and water
trap. Air pressure (90 lbs. minimum) is supplied
to the air intake valve located near the bottom of
the cabinet on the left side. The pressure
regulator should be adjusted to 90-120 lbs.
12.9 Air Prep Unit
Referring to Figure 14:
Required Maintenance
Check weekly.
Drain water from the trap when the level
exceeds the redline.
Figure 14