This .pdf document is bookmarked Operating Instructions and Parts Manual Metalworking Dust Collection Stand Model JDCS-505 JET 427 New Sanford Road LaVergne, Tennessee 37086 Ph.: 800-274-6848 www.jettools.com Part No.
12. Make certain the switch is in the OFF position before connecting the machine to the power supply. Turn off all controls before unplugging. 13. Make certain the machine is properly grounded. Connect to a properly grounded outlet only. See Grounding instructions. 1.0 IMPORTANT SAFETY INSTRUCTIONS 14. Make all machine adjustments or maintenance with the machine unplugged from the power source. When using an electrical appliance, basic precautions should always be followed, including the following: 15.
27. Do not use this dust collector with a damaged cord or plug. If the unit is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to a service center. 33. Use recommended accessories; accessories may be hazardous. improper 34. Maintain tools with care. Follow instructions for lubricating and changing accessories. 35. Turn off machine and disconnect from power before cleaning. Use a brush or compressed air to remove chips or debris; do not use bare hands.
3.0 Table of contents Section Page 1.0 IMPORTANT SAFETY INSTRUCTIONS ....................................................................................................... 2 2.0 About this manual .......................................................................................................................................... 3 3.0 Table of contents............................................................................................................................................ 4 4.
4.0 Specifications Model number ........................................................................................................................................ JDCS-505 Stock number .............................................................................................................................................. 414800 Motor and electricals: Motor type .....................................................................................................................
Dust ports: Main dust port, outside diameter ................................................................................................. 5 in. (127 mm) Inlet adaptor ports, outside diameter............................................................................... two at 3 in. (76.2 mm) Weights: Net weight ............................................................................................................................... 92.4 lb. (41.9 kg) Shipping weight ...............................
4.1.
5.5 Mounting a tool Read and understand the entire contents of this manual before attempting assembly or operation. Failure to comply may cause serious injury. Position tool, such as grinder or sander (not provided) atop stand and secure with fasteners through the hole/slot pattern. Connect 3-inch dust hose (optional accessory) to inlet adaptor port and tool, and secure with hose clamps. 5.0 Setup and assembly IMPORTANT: An inlet port that is not used during operation should be capped.
This appliance is rated more than 15 A and is for use on a circuit having a nominal rating of 120 V. It is factory-equipped with a specific electric cord and plug to permit connection to a proper electric circuit. Make sure that the appliance is connected to an outlet having the same configuration as the plug. No adaptor should be used with this appliance. If the appliance must be reconnected for use on a different type of electric circuit, the reconnection should be made by qualified service personnel. 6.
7.0 Operations 7.1 Main switch Pull out on switch (A, Figure 6) to start machine. Green power indicator lamp (B) will illuminate. Push switch in to stop machine. (Power indicator lamp will turn off.) 7.2 Safety Key The safety key (C, Figure 6) prevents unauthorized use of machine. Remove key to deactivate switch. Key must be reinserted to start machine – press until it snaps back in. Figure 7 8.0 User-maintenance Always disconnect power to the machine before performing maintenance.
10.0 Replacement Parts To order parts or reach our service department, call 1-800-274-6848 Monday through Friday, 8:00 a.m. to 5:00 p.m. CST. Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately.
10.1.2 JDCS-505 Grinder Stand – Parts List Index No Part No Description Size Qty 1 ................ JDCS505-01.............. Motor........................................................................ 1/2 HP ........................... 1 .................. JDCS505-RC ............ Run Capacitor (not shown) ...................................... 300VAC 15μF ............... 1 2 ................ F000299 .................... Phillips Pan Head Screw ......................................... 1/4 x 1/2 in. ..
Optional parts: .................. 414830 ...................... Adaptor Plate Kit * (incl. #47 thru 51) ...................... ...................................... 1 47 .............. .................................. Adaptor Plate *......................................................... ...................................... 1 48 .............. F012439 .................... Hex Flange Screw * ................................................. 5/16 x 1/2 in. ................. 4 49 ..............
11.
12.0 Warranty and service JET warrants every product it sells against manufacturers’ defects. If one of our tools needs service or repair, please contact Technical Service by calling 1-800-274-6846, 8AM to 5PM CST, Monday through Friday. Warranty Period The general warranty lasts for the time period specified in the literature included with your product or on the official JET branded website. • JET products carry a limited warranty which varies in duration based upon the product.
427 New Sanford Road LaVergne, Tennessee 37086 Phone: 800-274-6848 www.jettools.