Operating Instructions and Parts Manual AFS-2000 Air Filtration WALTER MEIER (Manufacturing) Inc. 427 New Sanford Road LaVergne, Tennessee 37086 Ph.: 800-274-6848 www.waltermeier.com Part No. M-708615 Revision B 03/2010 Copyright © 2010 Walter Meier (Manufacturing) Inc.
Warranty and Service Walter Meier (Manufacturing) Inc., warrants every product it sells. If one of our tools needs service or repair, one of our Authorized Service Centers located throughout the United States can give you quick service. In most cases, any of these Walter Meier Authorized Service Centers can authorize warranty repair, assist you in obtaining parts, or perform routine maintenance and major repair on your JET ® tools.
Table of Contents Warranty and Service..........................................................................................................................2 Table of Contents ...............................................................................................................................3 Warning .............................................................................................................................................3 Safety Rules for the AFS-2000 ......................
14. DON’T OVERREACH. Keep proper footing and balance at all times. 15. MAINTAIN TOOLS IN TOP CONDITION. Keep tools sharp and clean for best and safest performance. Follow instructions for lubricating and changing accessories. 16. DISCONNECT TOOLS before servicing and when changing filters. 17. USE RECOMMENDED ACCESSORIES. The use of accessories and attachments not recommended by manufacturer may cause hazards or risk of injury to persons. 18. AVOID ACCIDENTAL STARTING.
Safety Rules for the AFS-2000 1. Read and understand instruction manual before installing or operating air cleaner. 2. To reduce the risk of injury disconnect the air cleaner from the power source (unplug) before servicing or changing filters. 3. If ceiling mounted, bottom of air cleaner must be at least 7 feet above the floor. 4. If ceiling mounted, mounts must be anchored to building structure which will support a minimum of at least 220 pounds.
Electrical Requirements Electrical connections must be made by a qualified electrician in compliance with all relevant codes. This machine must be properly grounded to help prevent electrical shock and possible fatal injury. In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This tool is equipped with an electric cord having an equipment-grounding conductor and a grounding plug.
Unpacking Contents of Shipping Carton 1 1 2 4 1 1 Air Filtration Unit Remote Control AAA Batteries Eye Bolts, Washers and Hex Nuts Owner's Manual (not shown) Warranty Card (not shown) Tools Required for Assembly 10 mm Wrench • The air filtration unit does not require muc h assembly. You should take into consideration how and where you will place this unit. • This unit will work best if it is located away from corners, and heating/cooling vents.
Controls and Features Remote Control: Time button (A, Figure 3) controls the three different settings. 2H will light up on the back of the unit with one press of the time button. The air filtration system will operate for 2 hours then shut off. 4H will light up on the back of the unit by pressing the time button twice. The air filtration system will operate for 4 hours then shut off. Figure 3 8H will light up on the back of the unit by pressing the time button three times.
Inner Filter: You must remove the two bolts (A, Figure 5) that hold the cover in place. Remove the cover. Remove the inner filter (A, Figure 6) from the side of the cabinet. Replace the cover and four bolts. Accessory Filter: An additional electrostatic filter can be added to this empty slot (B, Figure 6). Replace the cover and four bolts. Diffuser: The diffuser (A, Figure 7) should not need any maintenance. You can remove from the side of the cabinet.
Parts Breakdown 10
Parts List To order parts or reach our service department, call 1-800-274-6848, Monday through Friday (see our website for business hours, www.waltermeier.com). Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately. Index No. Part No. Description Size Qty 1 .............. 330001....................Fan Blade .......................................................................................... 1 2 .............. 330002.....
Index No. Part No. Description Size Qty 50 ............ 330030....................Bolt .................................................................................................... 2 51 ............ WS080000 ..............Spring Washer..................................................M8 ............................. 6 52 ............ BR000031 ...............Rivet .................................................................................................. 2 53 ............ AB001008 .........