User Manual

13
Electrical Connections
All electrical connections must
be done by a qualified electrician.
All adjustments or repairs must be done with the
dust collector disconnected from the power source,
unplugged. Failure to comply may result in serious
injury!
The DC-1100VX dust collectors (all models) are rated at
115/230V, Prewired 115V. Use a plug and outlet rated
at least 20 amps. The circuit for the machine should
also be protected by a minimum 20 amp circuit breaker
or fuse. Keep in mind that a circuit being used by other
machines, tools, lights, heaters, etc. at the same time
will add to the electrical load.
A dedicated circuit to the dust collector will give you the
best results since dust collectors are generally used at
the same time other tools are running.
Turning the Machine On & Off
This machine is intended for
indoor use only.
All Models
Before hooking up to the power source, make sure that
the switch is in the off position.
Turn the dust collector on by pressing the Start button
mounted next to the motor. Press the Stop button to turn
off the dust collector.
Remote Control (Optional Accessory)
The DC-RC RF Remote Power Control unit is available
as an optional accessory (see your dealer or contact
Customer Service by calling the number on the cover).
Important: The DC-RC Remote Power Control (SN
708636C) can be used for activating Dust Collection
units powered by 115V only up to 1-1/2HP. If your dust
collector is currently set up for 230V operation or you
choose to convert it to 230V at a later time, you must
purchase the DC-RC230 Remote Power Control unit
(SN 708636D).
Figure 13A Figure 13B
Dust Collector RF Remote
Power Control (Optional)
The DC-RC Remote Power Control (Figure 14) should
be used for activating Dust Collection units powered by
115V only up to 1-1/2HP. The DC-RC Remote Power
Control unit is rated at 115V, Single Phase only. Use an
outlet rated at least 20 amps. The circuit for the device
being controlled by the DC-RC should also be protected
by a minimum 20 amp circuit breaker or fuse.
Before hooking up to the power source, make sure that
the switch is initially in the off position on both the dust
collector and remote control unit (Figure 13).
Turning the DC-RC On & Off
This machine is intended for
indoor use only.
1. Plug the dust collector into the main unit
(Figure 14) and plug the main unit into the power
outlet.
To start a machine or device:
34. Turn the machine itself on.
35. On the main unit place the switch to the ON position
(Figure 13A). The red LED on the main unit should
light up.
36. Press the button on the remote control transmitter
(Figure 14) to turn the machine on.
37. To stop the machine, press the button on the
remote control transmitter again.
Figure 14
When the machine is running, it can be stopped by
placing the switch on the main unit in the off position