Operating Instructions and Parts Manual AFS-850 Air Filtration System JET 427 New Sanford Road LaVergne, Tennessee 37086 Ph.: 800-274-6848 www.jettools.com Part No.
1.0 IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precautions should always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS AIR FILTRATION UNIT. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. To reduce the risk of fire, electric shock, or injury: Read and understand the entire owner's manual before attempting assembly or operation.
Familiarize yourself with the following safety notices used in this manual: This means that if precautions are not heeded, it may result in minor injury and/or possible machine damage. This means that if precautions are not heeded, it may result in serious, or possibly even fatal, injury.
2.0 Table of contents Section Page 1.0 IMPORTANT SAFETY INSTRUCTIONS ....................................................................................................... 2 2.0 Table of contents............................................................................................................................................ 4 3.0 About This Manual ......................................................................................................................................... 5 4.
3.0 About This Manual This manual is provided by JET, covering the safe operation and maintenance procedures for a JET Model AFS850 Air Filtration System. This manual contains instructions on installation, safety precautions, general operating procedures, maintenance instructions and parts breakdown. Your machine has been designed and constructed to provide consistent, long-term operation if used in accordance with the instructions as set forth in this document.
4.0 Features • • • • • • • • Large easy to read display panel clearly shows: o Filter Status § Bright LED indicators notify the user of the filter status. • GOOD • REPLACE SOON • REPLACE o Fan Speed – 6 levels o Timer Setting § 1 to 16 hours in 1-hour increments § Automatically shuts off when timer runs out High-Efficiency Brushless DC Motor o Improved durability o Quieter operation o More energy efficient Auto Mode: o In Auto Mode the unit monitors ambient air quality using an integrated PM2.
5.0 Specifications Table 1 Model No. AFS-850 Stock No. JT1-229 SPECIFICATION Motor: Motor type BLDC (Brushless Direct Current Motor) Horsepower 1/5HP Phase 3PH Electrical: Voltage 120V input, single phase only Frequency 60Hz Listed FLA (full load amps) 2.5 A Motor speed range 1500~2500 RPM Power cord SJT 18 AWG x 3C, 0.
Table 1 (cont.) Dimensions and Weight: 1 Overall Dimensions (L x W x H / in) 19.134" x 19.134" x 36.575" (486 x 486 x 929 /mm) Packing Dimensions (L x W x H / in) 20.866" x 20.866" x 41.969" (530 x 530 x 1066 /mm) Net Weight 31.9 Ib (14.5 kg) Gross Weight 40.39 lb (18.36 kg) Variable of ±10%, for general information only, not to be viewed as fixed parameters for inspection purposes.
7.0 Electrical Connections Read and understand the entire contents of this manual before attempting to install and operation. Failure to comply may cause serious injury. Electrical connections should be made by a qualified electrician in compliance with all relevant codes. Failure to comply may cause serious injury. 6.0 Setup The AFS-850 Air Filtration System is prewired for single phase, 120V power.
POWER ON/OFF SWITCH – A The Power ON/OFF Switch (Fig. 8-1, A) is a rocker switch on the control panel used to supply power to the AFS electronic controls and thus the full AFS. In the OFF position, AC power is disconnected from the electronics. The AFS unit will not turn On. In the ON position, AC power is connected to the electronics. The electronics are powered On in a STANDBY state awaiting user input via the ON/OFF Button (B). Figure 7-1 7.
AUTOMATIC MODE Button will add or subtract time from the already set value. • When the TIMER + or – Button have been pressed, the number on the TIMER Display will flash for 1 second and then show steady ON. Steady ON indicates the TIMER is set and the countdown has begun. • Pressing and holding either the TIMER + or – Button (2 seconds) will advance the count quickly (changing every 0.2 seconds) until the button is released.
9.0 Operation NOTE: The Air Filtration Unit is designed to remove airborne, non-metallic dust particles; it is not designed to take the place of a dust collection system. Larger particles are trapped by the Pre-Filter. Smaller particles are stopped by the Canister Filter. The clean air is then exhausted through the impellers at the top of the machine. IMPORTANT: Do not block the top of the Fan Head or any portion of the perforated Steel Barrel. Normal operation: • Place Power On/Off Switch to ON.
5. 10.2 Cleaning the Filters Remove the Pre-Filter from the Canister Filter (see Figure 10-3). To reduce the risk of injury, disconnect the air filtration system from the power source (unplug) before servicing or changing filters. Failure to comply may cause serious injury! This AFS is designed to remove airborne nonmetallic dust particles from the air. Cleaning is about removing those particles from the filter in the opposite direction from which they came.
• 2. Visually inspect the filter while cleaning. If the filter material is worn, torn, or coming apart from the frame, it must be replaced. The screen flashes and displays “- -", the calibration is completed when the detected value is stable (- - disappears), and then returns to the standby state. 10.4 Cleaning Sensors Dust may accumulate on the sensor (see Fig. 8-3) and affect the performance in AUTO mode. Clean the Sensor with a dry cloth or compressed air. 10.
11.0 Troubleshooting Table 4 Symptom Probable Cause Remedy Power ON/OFF Switch in the OFF position Move Power ON/OFF Switch to the ON position. No incoming power Check plug connection Verify there is power at the outlet, check breaker or fuse panel. Low voltage Request voltage check form power company and correct low voltage condition. Power cord damaged Replace power cord. Control button or PCBA malfunction Contact JET customer service.
12.0 Replacement Parts Replacement parts are listed on the following pages. To order parts or reach our service department, call 1-800274-6848 Monday through Friday, 8:00 a.m. to 5:00 p.m. CST. Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately. 12.1.
12.1.2 AFS-850 Unit – Parts List Index No Part No Description Size Qty 1 ................ AFS850-001 .............. Mesh guard .............................................................. ..................................... 1 2 ................ AFS850-002 .............. Motor ....................................................................... ...................................... 1 3 ................ AFS850-003 .............. Fan body ............................................................
12.2.1 Display Module Assembly – Exploded View 12.2.2 Display Module Assembly – Parts List Index No Part No Description Size Qty 6 ................ AFS850-DMA ............ Display module assembly ........................................ ...................................... 1 6-1 ............. AFS1000C-DM1 ........ AC power switch ...................................................... ...................................... 1 6-2 ............. AFS850-DM2 ............ Display label .....................
12.4.1 Plastic Base Cover Assembly – Exploded View 12.4.2 Plastic Base Cover Assembly – Parts List Index No Part No Description Size Qty 20 .............. AFS850-PBCA .......... Plastic base cover assembly ................................... ...................................... 1 20-1 ........... AFS850-PBC1........... Plastic base cover ................................................... ...................................... 1 20-2 ........... AFS850-PBC2........... Counterweights .................
13.
14.0 Warranty and Service JET warrants every product it sells against manufacturers’ defects. If one of our tools needs service or repair, please contact Technical Service by calling 1-800-274-6846, 8AM to 5PM CST, Monday through Friday. Warranty Period The general warranty lasts for the time period specified in the literature included with your product or on the official JET branded website. • JET products carry a limited warranty which varies in duration based upon the product.
NOTES 22
NOTES 23
427 New Sanford Road LaVergne, Tennessee 37086 Phone: 800-274-6848 www.jettools.