User manual

RX/TX: Item RX shows the unic production number of the receiver. Item TX shows the unic production number of the
transmitter, to which the receiver has eventually been paired.
Rx Diag: Item A1 or A2 shows which antenna the receiver is using at present. Item Kx informs about the number of
transferred channels (this number depends of the transmitter abilities).
By means of key D (arrow down) you arrive at the line of basic mode selections, where you may select read out of
measured values (Measure) or setup of the receiver (Main setting, Channel set, Out Pin Set, Auto Set).
Measure: enables read out of measured data of the maximum, minimum and actual receiver voltage.
-Volt Min / Act / Max : the receiver is checking the supply voltage and indicates limit values and extremes which
occurred during operation; at the same time it also shows the actual receiver voltage. Without switching on the paired
transmitter the values MAX and MIN will not change, only the value of the actual voltage ACT will be updated. In order
to delete values MAX and MIN, keys L (arrow left) and R (arrow right) must be pressed simultaneously.
Main setting: Basic setup, here you may adjust general properties of the receiver which are common to all output
channels.
- Signal Fault Delay: specifies the deadline after which the receiver outputs change due to signal loss to
preadjusted positions of the particular outputs or after which they become switched off (due to setup of Signal Fault
in the menu Out Pin Set).
- Volt act/alarm: the first item shows the actual receiver supply voltage, the second value serves for the setup of
the alert decision threshold. As soon as during operation the actual voltage decreases below the set threshold, the
transmitter will announce this situation by an acoustic tone.
- Output Period: setup of the output signal period (standard setup 20ms), analog servos respond faster with lower
values (shorter response time) and consume more current. If the value is set too low some servos may chatter. The
output period may also be synchronized with the transmitter - Output Period - By Transmitter.
-RX mode: this setup switches the receiver to monitoring mode (Clone). This mode should only be used in
applications with two or more receivers, working simultaneously in a model in connection with a single transmitter
module. One receiver should work as master receiver (Normal) and the others in monitoring mode (Clone). The mode
change (Normal / Clone) must be carried out only with the JETIBOX connected directly to the receiver.Telemetric
sensors can be operated with a receiver in Normal mode only.
-PPM Output mode (applicable to RSat receivers only) Setup of the satellite receiver mode
-Computed: the signals received from the transmitter can be processed furtheron in the receiver
and its menus Channel setand Out Pin Set(mixers, programmable channel outputs a.s.o.)
-Direct: signals received from the transmitter are notfurtheron processed in the receiver, they are
generated without any change at the output of the sallite receiver in form of PPM signals
-Number of PPM Output Pulses: (valid for RSat and RMK) Setup of PPM pulse number at the Rsat receiver. If there
are transmitted less channels than the set number of PPM pulses at the receiver, then the remaining pulses will be
replaced by one pulse with a length corresponding to the pulse length adjusted in the FailSafe menu of the given
channel. In the reverse case the number of output pulses will be reduced to the default setting number.
EN
Receivers