Operation Manual

8 9
FP14-16-GBwww.jilong.com FP14-16-GBwww.jilong.com
Operating Instructions
1. Make sure the pool is already lled with water and place the Filter Pump at
suitable position.
2. With water owing into the lter pump, the water pressure will allow the air
entered inside to escape from the air release valve (P1).
3. Then gently finger tighten the air release valve (P1) in a clockwise
direction.
4. Connect the power supply cord of adapter to AC 230V to operate the Filter
Pump until the clarity of the water in pool is obtained.
General Maintenance
1. Disconnect power to motor before working on pump or motor.
2. Depending on the parts usage, keep some spare available, strongly
command to have two Filter Cartridges for spare use.
3. No lubrication or regular mechanical maintenance are needed.
4. Wash outside of filter with a mild detergent and water, rinsing off with
hose.
5. Do not use solvents to clean filter; solvents may damage plastic
components in system.
6. Maintain pH level at 7.0 to 7.4 in pool.
7. The voltage of adapter is AC 230V.
8. Do not place the Filter Pump in tall grass it might cause the motor’s
overheating.
9. After pool water is completely emptied out, remove all pool hoses from
pool and Filter-Pump.
10. Exhaust water from all housings of the Filter Pump.
11. Store all lter pieces in a dry storage location and with ventilation. Before
storage, make sure all parts are dry.
12. You can store the Filter Pump in a dry location and take advantage of the
original packing carton for storage for next season usage.
Cleaning and Replacement
1. Make sure the 230 V adapter disconnect the power supply cord from the
electric outlet.
2. In a counter-clockwise direction to remove the Filter chamber cover
retainer (P3). Place it in a safe location.
3. Clean the used Filter Cartridge (P6) or replace it if necessary.
4. Check the inside of the Filter chamber (P7).
5. If dirt or sediment is found on the bottom of the housing then e.g. with a
bucket of water or a garden hose to ush the housing out of sediment or dirt.
6. Return the Filter chamber cover retainer (P3) to its position and in a
clockwise direction to fasten onto the Filter Housing.
7. Reconnect the power supply cord of adapter.
Trouble Shooting Guide
PUMP DOES NOT OPERATE:
A. Check for blown fuses, circuit breakers, or
disconnected electrical wiring.
B. Check motor. If motor is too hot or overlaod shutit off. Let motor cool down.
C. Consult expert.
MOTOR RUNS, BUT DOES NOT PUMP WATER OR WATERFLOW IS TOO
SLOW:
A. Check for obstructions in intake hose or discharge hose
inside pool wall.
B. Tighten hose clamps, check hoses for damage, check pool water level.
C. Clean filter cartridge more often. Reusable and easy to clean e.g. with
garden hose.
D. Replace lter cartridge.
E. Consult expert.
PUMP LOSES PRIME
A. Make sure water level in pool is at least 5 cm above
bottom of skimmer throat with system not operating.
B. Make sure there are no leaks in suction piping.
C. Check if the lter cartridge is dirty and needs cleaning. Reusable and easy
to clean e.g. with garden hose.
D. Consult export.
FILTER DOES NOT CLEAN POOL
A. Adjust chlorine and pH level.
B. Clean or replace filter cartridge. Reusable and easy to clean e. g. with
garden hose.
C. Check for holes in cartridge. Replace if damaged.
D. Let pump operate more longer.
E. Clean away debris from strainer screen at pool wall.
F. Consult expert.