Revised - June, 2018 VSeries Acidic Condensate Wastewater and Air Conditioning Non-Acidic Wastewater Removal System Models: V-125 V-250 / V-250 Combi V-252 / V-253 Installation Operation & Maintenance 14 Coleman Ave. Westfield, MA 01085 413-527-1893 690 Island Way Unit 206, Clearwater, FL 33767 413-427-3373 jjmboilerworks.
ALL JJM NEUTRALIZING PRODUCTS ! WARNING JJM neutralizers are sized by BTU input to establish a flow rating. Job site conditions will determine neutralizer design. See GPH chart below. How much fireside condensate will my equipment develop? Hot water heaters / Boilers / Furnaces / Economizers Equipment Efficiency 90% 91% 92% 93% 94% 95% 96% 97% 98% 99% GPH Condensate .725 / Per 100,000 BTU Input .733 / Per 100,000 BTU Input .741 / Per 100,000 BTU Input .750 / Per 100,000 BTU Input .
Vseries Acidic Condensate pH Treatment Kits –– Installation/Operation & Maintenance Maintenance ! DANGER Inspect frequently Indicates a condition or hazard which will cause severe personal injury, death or major property damage. Installer — Instruct the building owner to frequently inspect the V Series cannister cartridge neutrazlier and all condensate connections. The owner must notify a qualified technician if any problems are noticed.
Vseries Acidic Condensate pH Treatment Kits –– Installation/Operation & Maintenance Overview What is pH? Read before proceeding The pH measurement of a fluid is an indicator of the acidity or alkalinity. Neutral fluids have pH of 7.0. Acid fluids have pH below 7. And alkaline fluids have pH above 7 (up to 14). The pH can be easily measured using digital pocket pH probe Condensate pH from condensing boilers and furnaces is typically around 4.
Vseries Acidic Condensate pH Treatment Kits –– Installation/Operation & Maintenance Installation Figure 1 Piping diagram for wall hung heater/V Series vertical pH treatment canister to drain. BOILER OR HOT WATER HEATER LEGEND 1. Flue Pipe 2. Trap 3. V-250 Inlet 4. V-250 Outlet 5. Drain Line 6. Drain 7. V-250 / V-125 8. Tee Vent Open To Atmosphere Figure 2 Piping diagram for wall hung heater/V-Series vertical pH treatment canister with receiver pump.
Vseries Acidic Condensate pH Treatment Kits –– Installation/Operation & Maintenance Installation Figure 3 Piping diagram for wall hung heater / V-252 vertical pH treatment canisters. LEGEND 1. Flue Pipe 2. Trap 3. V-252 Inlet 4. V-252 Outlet 5. Drain Line 6. Drain 7. V-252 8. Tee Vent Open To Atmosphere B2 B1 BOILER OR HOT WATER HEATER MODEL MBH GPH V-252 500 3.80 Figure 4 Piping diagram for wall hung heater / V-253 vertical pH treatment canisters. LEGEND 1.
Vseries Acidic Condensate pH Treatment Kits –– Installation/Operation & Maintenance Installation V-125 CANISTER Figure 5 Exploded View of V-125 rev. 12/19/17 RATING: 125 MBH RATING: 125 MBH INLET/OUTLET PORT 1/2” NPT 4.5” 9.375” 6.
Vseries Acidic Condensate pH Treatment Kits –– Installation/Operation & Maintenance Installation Figure 6 Exploded View of V-250 412" 5 Bracket 4.5" x 2.5" x 3"deep 212" 1 4 Bracket Screws 4x, 8-18 x 1" 2 3 4 Bracket Screws 4x, 8-18 x 1" JJM Boiler Works, Inc. V-250 Part Numbers DETAIL Figure 7 WORKS Exploded JJM BOILER INC.
Vseries Acidic Condensate pH Treatment Kits –– Installation/Operation & Maintenance V-250 CANISTER rev.
Vseries Acidic Condensate pH Treatment Kits –– Installation/Operation & Maintenance Installation Figure 10 V-252 dimensions 6.5” 10.75” + + + + + + + + 6.5” 14.5” 14.5” 10.75” Figure 11 V-253 dimensions 17.375” 6.5” + + + + + + + + 14.5” 14.5” 17.375” 6.5” 17.375” + + + + + + + + + + + 6.5” 14.
Vseries Acidic Condensate pH Treatment Kits –– Installation/Operation & Maintenance Installation Figure 12 V-125, V-250, V-252 & V-253 / Wall Mounting V-200 Vertical Mount Canister 1/2” x 4” Single Stud Wall Mount 1/2” x 4” Double Stud Wall Mount STUD STUD STUD Mount at least 1 3/4” above floor FLOOR Install all electrical wiring in accordance with the National Electrical Code and local requirements.
Vseries Acidic Condensate pH Treatment Kits –– Installation/Operation & Maintenance Installation Maintenance Procedures Getting the most out of your JJM® Neutralizer Acidic wastewater neutralizers like all filtering devices need both maintenance and replacing. The average pH level of acidic wastewater produced by today’s condensing boilers, hot water heaters, furnaces, flue stack drains, and stack economizers is 3.2pH.