Page 11
|
TUNE TAB
“EQUALIZERS” Panel:
Reorder: Re-establishes numerical order (1-10) of parametric EQ band
labels in order of center frequency, from low to high.
(Parametric EQ only)
All Reset: Resets all EQ bands to their default values
All O/On: Temporarily defeats/turns on all EQ bands
EQ Select: Select an EQ to adjust from the pull-down menu (Linked
EQ’s are shown as pairs).
EQ Link:
Allows Le and Right EQ Banks to be linked and adjusted
together, with identical settings.
Numerical Entry of EQ values: You can directly enter numerical values
for EQ adjustment into the following entry elds. Use the up/down
arrow icons in each eld for incremental adjustment. Holding the
Shi-Key down while clicking the arrows results in ner resolution. e
following entry elds are available:
FREQ: e center frequency of the EQ band. Default values are in
accordance with ISO full octave EQ band specications: 31, 63, 125,
250, 500, 1000, 2000, 4000, 8000 and 16000 Hz. ese values are
xed in Graphic EQ mode and variable in Parametric EQ mode.
“Q”: e shape of the EQ lter response. Lower “Q” values result
in wider bandwidth EQ lter response. Higher “Q” values result
in narrower bandwidth EQ lter response. is value is xed in
Graphic EQ mode and variable in Parametric EQ mode from 0.26
to 10. Default value is 1.41.
Gain: e amount of amplitude boost or cut applied through the
selected lter, expressed in decibels and adjustable from +6 dB to
–12 dB. Default value is 0 dB. is control is available in Graphic
and Parametric EQ modes.
Manual EQ adjustment on the display graph: e Graphic EQ
uses familiar “slider” control graphics. In Parametric EQ mode, the
numbered, round EQ Band labels on the display graph can be directly
selected and moved using the mouse/touchpad. e graph will display
the resulting eect on frequency response in real time. e resulting
value changes will also be reected in the EQ numerical entry elds.
Manual commands:
Le Click and Hold, then Drag Up/Down for Boost/Cut
Le Click and Hold, then Drag Le/Right to change Center
Frequency (Parametric EQ only)
Right Click and Hold, then Drag Up/Down or Le/Right to change
“Q” (Parametric EQ only)
Control+Le Click to select multiple EQ bands. ese can then be
adjusted together.