Operator Manual User guide

SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
6-16 – JLG Lift – 3121141
6.3 OPERATOR MAINTENANCE
NOTE: The following numbers correspond to those in Figure 6-5., Lubri-
cation and Maintenance Point Location.
LUBRICATION INTERVALS ARE BASED ON MACHINE OPERATION UNDER NORMAL CON-
DITIONS. FOR MACHINES USED IN MULTI-SHIFT OPERATIONS AND/OR EXPOSED TO
HOSTILE ENVIRONMENTS OR CONDITIONS, LUBRICATION FREQUENCIES MUST BE
INCREASED ACCORDINGLY.
NOTE: It is recommended as a good practice to replace all filters at the
same time.
1. Swing Bearing - Remote Lube
Lube Point(s) - 2 Grease Fitting
Capacity - A/R
Lube - MPG
Interval - Every 3 months or 150 hours of operation
Table 6-18. Lubrication Specifications
KEY SPECIFICATIONS
MPG Multipurpose Grease having a minimum dripping point of 350° F (177° C). Excel-
lent water resistance and adhesive qualities, and being of extreme pressure type.
(Timken OK 40 pounds minimum.)
EPGL Extreme Pressure Gear Lube (oil) meeting API service classification GL-5 or MIL-
Spec MIL-L-2105
HO Hydraulic Oil. API service classification GL-3, e.g. Mobilfluid 424.
EO Engine (crankcase) Oil. Gas - API SF, SH, SG class, MIL-L-2104. Diesel - API CC/CD
class, MIL-L-2104B/MIL-L-2104C.