Service Manual Manual

SECTION 6 - JLG CONTROL SYSTEM
3121171 – JLG Lift – 6-27
SWING:
ACCEL X.Xs Displays/adjusts swing acceleration 0.1 to 5.0 sec 2.0
DECEL X.Xs Displays/adjusts swing deceleration 0.1 to 3.0 sec 1.5
MIN LEFT XX%
Displays/adjusts minimum swing left
speed
0 to 50% 20
MAX LEFT XXX%
Displays/adjusts maximum swing left
speed
0 to 65% 73
102-146 (see
orientation)
CREEP LEFT XX%
Displays/adjusts maximum swing left
speed
NOTE: used when creep switch on pump
pot is active
0 to 65% 45
MIN RIGHT XX%
Displays/adjusts minimum swing right
speed
0 to 50% 20
MAX RIGHT XXX%
Displays/adjusts maximum swing right
speed
0 to 65% 65
102-146 (see
orientation)
CREEP RIGHT XX%
Displays/adjusts maximum swing right
speed
NOTE: used when creep switch on pump
pot is active
0 to 65% 45
TOWER LIFT:
ACCEL X.Xs Displays/adjusts tower lift acceleration 1.0 to 1.0 sec 1.0
DECELSLOW-FAST Displays/adjusts tower lift deceleration
Slow, Medium,
Fast
0.5
MIN Up XX%
Displays/adjusts minimum tower lift up
speed
1 to 1% 1
MAX UP XX%
Displays/adjusts maximum tower lift up
speed
60 to 60% 60
105-119 (see
orientation)
MIN DOWN XX%
Displays/adjusts minimum tower lift down
speed
1 to 1% 1
MAX DOWN XXX%
Displays/adjusts maximum tower lift
down speed
60 to 60% 60
108-122 (see
orientation)
MAIN TELESCOPE:
ACCEL X.Xs
Displays/adjusts main telescope acceler-
ation
0.1 to 5.0 sec 1.5
DECEL X.Xs
Displays/adjusts main telescope deceler-
ation
0.1 to 3.0 sec 0.5
MIN IN XX%
Displays/adjusts minimum main tele-
scope in speed. Same as Creep speed
0 to 65% 40
MAX IN XXX%
Displays/adjusts maximum main tele-
scope in speed
0 to 100% 85
35-54 (see
orientation)
MIN OUT XX%
Displays/adjusts minimum main tele-
scope out speed. Same as Creep speed
0 to 65% 40
MAX OUT XXX%
Displays/adjusts maximum main tele-
scope out speed
0 to 100% 85
29-49 (see
orientation)
Table 6-4. Machine Personality Settings and Speeds