Service Manual Manual

SECTION 6 - JLG CONTROL SYSTEM
6-54 – JLG Lift – 3121171
10. Press ENTER.
11. When prompted, swing turntable 180° to opposite
end of chassis.
12. Press ENTER. The screen should read:
13. Upon completing swing calibration, swing turntable
180° back to the stowed position.
14. Hit ESC twice to go back to CALIBRATIONS.
6.17 BOOM SENSOR CALIBRATION
To begin calibration of the boom sensors, the following
conditions must be met:
Successful completion of the steering sensor and
tilt sensor calibrations
The axles are completely extended
The wheels are straight
The platform is unloaded and booms are clean
The jib is fully raised
The jib swing is centered
The platform is level
The platform is not rotated
The turntable is centered between the rear tires
The tower boom is fully retracted
The tower boom is fully lowered
The main boom is fully retracted
The main boom is fully lowered
The machine indicates that it is on a level surface
(within ±1.5
Ground Mode is selected
General Notes:
During all Control System lag times the analyzer
should display “CALIBRATING…”
After each “ENTER” input and before the
Control System records sensor values, the Control
System will wait 10 seconds for the boom activity
to settle down before readings are taken.
During calibration, if the ESC key is pressed
after the calibration procedure is started, the cali-
bration will be aborted and “CAL FAILED” will be
displayed on the bottom line of the analyzer and
the previous calibration values will be used for the
boom sensors. The analyzer will continue to dis-
play “CAL FAILED” and follow the electrical
retrieval system sequence for positions of back-
ward stability concern until all transport positions
are met or the power is cycled. Refer to Section
4.9, Electrical Retrieval System.