Service Manual User Manual
9-41
3614RS, 4017RS
Electrical System
AUXILIARY
FUNCTION-B VALVE –
OPEN CIRCUIT
33199 5000Ms
Auxiliary Function-B is prevented
Continuous Auxiliary Hydraulics is
prevented
Auxiliary Release is prevented
Open-circuit is detected on UGM J2-
20
Power cycled
AUXILIARY
FUNCTION-B VALVE –
SHORT TO GROUND
33200 Continuously
Auxiliary Function-A is prevented
Auxiliary Function-B is prevented
UGM J3-14 Aux Return is disabled
Continuous Auxiliary Hydraulics is
prevented
Auxiliary Release is prevented
Short to ground is detected on UGM
J2-20
Power cycled
STABILIZER/FRAME
LEVEL SPEED VALVE –
OPEN CIRCUIT
33201 5000Ms
Stabilizers are prevented
Frame Level is prevented
Open-circuit is detected on UGM J1-
3
Power cycled
STABILIZER/FRAME
LEVEL SPEED VALVE –
SHORT TO BATTERY
33202 Continuously
Stabilizers are prevented
Frame Level is prevented
UGM J3-5 Stabilizer / Frame Level
Speed Return is disabled
Short to battery is detected on UGM
J1-3
Power cycled
STABILIZER/FRAME
LEVEL SPEED VALVE –
SHORT TO GROUND
33203 Continuously
Stabilizers are prevented
Frame Level is prevented
UGM J3-5 Stabilizer / Frame Level
Speed Return is disabled
Short to ground is detected on UGM
J1-3
Power cycled
LEFT STABILIZER
DOWN VALVE – OPEN
CIRCUIT
33222 5000Ms
Left & Right Stabilizer Down is
prevented
Open circuit is detected on UGM J2-
21
Power cycled
LEFT STABILIZER
DOWN VALVE –
SHORT TO BATTERY
33223 Continuously
Stabilizers are prevented
Frame Level is prevented
Short to battery is detected on UGM
J2-21
Power cycled
LEFT STABILIZER
DOWN VALVE –
SHORT TO GROUND
33224 5000Ms
Left & Right Stabilizer Down is
prevented
Short to ground is detected on UGM
J2-21
Power cycled
LEFT STABILIZER UP
VALVE – OPEN
CIRCUIT
33225 5000Ms Stabilizers are prevented
Open circuit is detected on UGM J2-
10
Power cycled
LEFT STABILIZER UP
VALVE – SHORT TO
BATTERY
33226 Continuously
Stabilizers are prevented
Frame Level is prevented
Short to battery is detected on UGM
J2-10
Power cycled
LEFT STABILIZER UP
VALVE – SHORT TO
GROUND
33227 5000Ms Stabilizers are prevented
Short to ground is detected on UGM
J2-10
Power cycled
RIGHT STABILIZER
DOWN VALVE – OPEN
CIRCUIT
33228 5000Ms
Left & Right Stabilizer Down is
prevented
Open circuit is detected on UGM J2-
15
Power cycled
RIGHT STABILIZER
DOWN VALVE –
SHORT TO BATTERY
33229 Continuously
Stabilizers are prevented
Frame Level is prevented
Short to battery is detected on UGM
J2-15
Power cycled
RIGHT STABILIZER
DOWN VALVE –
SHORT TO GROUND
33230 5000Ms
Left & Right Stabilizer Down is
prevented
Short to ground is detected on UGM
J2-15
Power cycled
RIGHT STABILIZER UP
VALVE – OPEN
CIRCUIT
33231 5000Ms Stabilizers are prevented
Open circuit is detected on UGM J2-
3
Power cycled