Service Manual Instruction Manual

Table Of Contents
SECTION 4 - BOOM & PLATFORM
3121616 – JLG Lift – 4-11
7. Remove stop tube if installed.
8. Actuator has timing marks for proper engagement.
9. Before removing shaft, (2), use a felt marker to clearly
indicate timing marks between shaft and piston. This
simplifies timing during assembly.
10. Remove shaft (2). It may be necessary to strike threaded
end of shaft with a rubber mallet.