- Section A. Introduction - Maintenance Safety Precautions
- Section 1. Specifications
- Section 2. General
- Section 3. Chassis & Turntable
- 3.1 Tires And Wheels
- 3.2 Torque Hub
- Oil Information
- Roll and Leak Testing
- Tightening and Torquing Bolts
- Main Disassembly
- Output Carrier Disassembly
- Input Carrier Disassembly
- Hub-Spindle Disassembly
- Spindle-Brake Disassembly
- Cover Disassembly
- Cover Assembly
- Input Carrier Sub-Assembly
- Output Planet Gear Sub-Assembly
- Spindle - Brake Sub-Assembly
- Hub-Spindle Sub-Assembly
- Cover Sub-Assembly
- Main Assembly
- Integral Brake Check
- 3.3 Free Wheeling Option
- 3.4 Drive Motor
- 3.5 Oscillating Axle Bleeding Procedure and Lockout Test
- 3.6 Steer Adjustments
- 3.7 Swing Drive
- 3.8 Swing Bearing
- 3.9 Swing Brake - Mico
- 3.10 Rotary Coupling
- 3.11 Generator
- 3.12 Deutz D2.9 L4 Engine
- 3.13 Deutz D2011 Engine
- 3.14 Spark Arrester Cleaning Instructions
- 3.15 Glow Plugs
- 3.16 Deutz EMR 2
- 3.17 Bio Fuel in Deutz Engines
- 3.18 GM Engine General Maintenance
- 3.19 GM Engine Dual Fuel System
- Fuel Filter
- Direct Electronic Pressure Regulator (DEPR)
- Air Fuel Mixer
- Electronic Throttle Control (ETC)
- Electric Lock Off
- Engine Control Module (ECM)
- Heated Exhaust Gas Oxygen Sensor
- Gasoline Multi Point Fuel Injection System (MPFI)
- Gasoline Fuel Pump
- Gasoline Pressure And Temperature Sensor Manifold
- Fuel Filter
- Fuel Injector Rail
- Fuel Injector
- 3.20 GM Engine Fuel System Repair
- Propane Fuel System Pressure Relief
- Propane Fuel System Leak Test
- Propane Fuel Filter Replacement
- Direct Electronic Pressure Regulator (DEPR) Maintenance And Inspection
- Check/Drain Oil Build-Up In 2-Stage Vaporizer
- Air Fuel Mixer/Throttle Control Device Maintenance And Inspection
- Exhaust System And Catalytic Converter Inspection And Maintenance
- Temperature Manifold Absolute Pressure (TMAP) Sensor
- Throttle Body (ETC) Replacement
- Mixer Replacement
- Electronic Pressure Regulator (EPR) Replacement
- Regulator Replacement
- Coolant Hose Replacement
- Vapor Hose Replacement
- Engine Control Module Replacement
- Heated Exhaust Gas Oxygen Sensor Replacement
- 3.21 GM Engine LPG Fuel System Diagnosis
- Section 4. Boom & Platform
- Section 5. Hydraulics
- 5.1 O-Ring Lubrication
- 5.2 Cylinders - Theory of Operation
- 5.3 Cylinder Checking Procedure
- 5.4 Cylinder Removal and Installation
- Cylinder Locations
- Main Boom Telescope Cylinder Removal
- Main Boom Telescope Cylinder Installation
- Main Boom Lift Cylinder Removal
- Main Boom Lift Cylinder Installation
- Upright Level Cylinder Removal
- Upright Level Cylinder Installation
- Tower Boom Lift Cylinder Removal
- Tower Lift Cylinder Installation
- Tower Telescope Cylinder Removal
- Tower Telescope Cylinder Installation
- 5.5 Hydraulic Cylinder repair
- Tower Boom Lift Cylinder
- Cleaning and Inspection
- Assembly
- Upright Level Cylinder
- Cleaning and Inspection
- Assembly
- Master Cylinder
- Cleaning and Inspection
- Assembly
- Main Boom Lift Cylinder
- Cleaning and Inspection
- Assembly
- Main Boom Telescope Cylinder
- Cleaning and Inspection
- Assembly
- Tower Boom Telescope Cylinder
- Cleaning and Inspection
- Assembly
- Platform Level (Slave) Cylinder
- Cleaning and Inspection
- Assembly
- Jib Lift Cylinder (AJ Only)
- Cleaning and Inspection
- Assembly
- Steer Cylinder
- Cleaning and Inspection
- Assembly
- Axle Lockout Cylinder
- 5.6 Hydraulic Pump (Gear)
- 5.7 Variable Pump
- 5.8 Hydraulic Component Start-Up
- 5.9 Pressure Setting Procedures
- Section 6. JLG Control System
- Section 7. Basic Electrical Information & Schematics

SECTION 7 - BASIC ELECTRICAL INFORMATION & SCHEMATICS
3121616 – JLG Lift – 7-3
Current Measurement
• Set up meter for expected current range
• Be sure to connect meter leads to correct jacks for
selected current range
• If meter is not auto ranging, set it to correct range (See
multi meter’s operation manual)
• Use firm contact with meter leads
7.3 APPLYING SILICONE DIELECTRIC COMPOUND
TO ELECTRICAL CONNECTIONS
NOTE: This section is not applicable for battery terminals.
JLG P/N 0100048 DIELECTRIC GREASE (NOVAGARD G661) IS THE ONLY MATE-
RIAL APPROVED FOR USE AS A DIELECTRIC GREASE.
NOTE: Do NOT apply dielectric grease to the following connec-
tions:
• Main Boom Rotary sensor connections (on Celesco Sensor),
• LSS Modules connections,
• Deutz EMR 2 ECM connection.
Silicone Dielectric Compound must be used on all electrical
connections except for those mentioned above for the follow-
ing reasons:
• To prevent oxidation at mechanical joint between male
and female pins.
• To prevent electrical malfunction caused by low level con-
ductivity between pins when wet.
Use the following procedure to apply Silicone Dielectric Com-
pound to the electrical connectors. This procedure applies to
all plug connections not enclosed in a box. Silicone grease
should not be applied to connectors with external seals.
1. To prevent oxidation, silicone grease must be packed
completely around male and female pins on the inside
of the connector prior to assembly. This is most easily
achieved by using a syringe.
NOTE: Over a period of time, oxidation increases electrical resis-
tance at the connection, eventually causing circuit failure.
2. To prevent shorting, silicone grease must be packed
around each wire where they enter the outside of the
connector housing. Also, silicone grease must be
applied at the joint where the male and female connec-
tors come together. Any other joints (around strain
reliefs, etc.) where water could enter the connector
should also be sealed.
NOTE: This condition is especially common when machines are
pressure washed since the washing solution is much more
conductive than water.
3. Anderson connectors for battery boxes and battery
chargers should have silicone grease applied to contacts
only.
NOTE: Curing-type sealants can also be used to prevent shorting
and would be less messy, but make future pin removal diffi-
cult.
When applied to electrical connections, dielectric grease helps
prevent corrosion of electrical contacts and improper conduc-
tivity between contacts from moisture intrusion. Open and
sealed connectors benefit from application of dielectric
grease.
Dielectric grease shall be applied to all electrical connectors at
the time of connection (except those noted under Exclusions).
Figure 7-4. Current Measurement (DC)