Service Manual Instruction Manual

Table Of Contents
SECTION 3 - CHASSIS & TURNTABLE
3-50 – JLG Lift – 3121616
3.11 GENERATOR
Every 250 hours
Check drive belt tension every 250 hours of operation,.
Every 500 hours
Service generator brushes and slip rings every 500 hours of
operation. Hostile environments may require more frequent
service.
Blow out inside of generator every 500 hours of service. If
operating in a hostile environment, clean monthly.
Table 3-8. Coupling Port Information Table - 2WS
Port
No.
Outlet
Port
Size
Description
Operating
Pressure
PSI (Bar)
Proof
Pressure
PSI (Bar)
1 1 -8 Brake 450 (31) 675 (47)
2 2 -6 2 Speed 4500 (310) 6750 (465)
3 1 -6 Steer 2500 (172) 3750 (259)
4 1 -6 Steer 2500 (172) 3750 (259)
5 2 -6, -16 Drive Reverse 4500 (310) 6750 (465)
6 1 -16 Drive Forward 4500 (310) 6750 (465)
7 3 -8, -6 Case Drain 250 (17) 375 (26)
Table 3-9. Coupling Port Information Table - 4WS
Port
No.
Outlet
Port
Size
Description
Operating
Pressure
PSI (Bar)
Proof
Pressure
PSI (Bar)
1 1 -8 Brake 450 (31) 675 (47)
2 2 -6 2 Speed 4500 (310) 6750 (465)
3 1 -6 Steer 2500 (172) 3750 (259)
4 1 -6 Steer 2500 (172) 3750 (259)
5 2 -6, -16 Drive Reverse 4500 (310) 6750 (465)
6 1 -16 Drive Forward 4500 (310) 6750 (465)
7 3 -8, -6 Case Drain 250 (17) 375 (26)
8 1 -6 Steer 2500 (172) 3750 (259)
9 1 -6 Steer 2500 (172) 3750 (259)


Figure 3-65. Generator Belt Tension
Figure 3-66. Generator Brushes and Slip Rings
Figure 3-67. Blow Out Generator